EXPERIMENTAL STUDY ON VIBRATION MITIGATION OF A STAY CABLE USING NONLINEAR HYSTERETIC DAMPERS

J. M. Ko,Y. Chen,G. Zheng,Y. Q. Ni
2000-01-01
Studies in Managerial and Financial Accounting
Abstract:This paper describes an experimental study on the cable vibration control using nonlinear hysteretic dampers. A 12n-long stay cable specimen, which is a 1:12 scale model of a 143m-long prototype cable in an actual cable structure, is established for the experimental study. Modal testing on the pure cable without damper is first performed to identify the actual modal properties of the cable under three different tension levels. Then a series of dynamic tests are conducted on the cable incorporated with a small-size wire-rope isolator near the lower anchorage. By exciting the cable transversely at a point near the upper anchorage, the nonlinear frequency response curves of the cable-damper system under different excitation force amplitudes and three installation positions of the damper are obtained experimentally. The resonant frequencies and the equivalent viscous damping ratios of the nonlinear system under different excitation levels are also identified, which are useful For the design analysis based on lineal vibration theory. The experiments show that the damping of the cable-damper system increases noticeably when the deformation of the damper attains a certain level. This feature should be beneficial to the mitigation of wind-rain-induced cable vibration because this type of vibration usually brings about large response amplitudes of the cable.
What problem does this paper attempt to address?