Experimental Study of Aquifer Physical Clogging During Artificial Recharge Process

SHAN Bei-Bei,ZHENG Xi-Lai,QIAO Zhen-Ji,LAN Xu-Shi
DOI: https://doi.org/10.16441/j.cnki.hdxb.2013.10.014
2013-01-01
Periodical of Ocean University of China
Abstract:The physical clogging process of aquifer was experimentally studied in laboratory by using a sand column.The space-time variation of permeability was measured to have a systematic analysis and evaluation on how to the concentration of suspended particles and hydrodynamic conditions influence the physical clogging,and to explore the mechanism of aquifer physical clogging.The research was showed that,the suspended particles were initially inclined to deposit at the surface layer with higher suspended particles concentration.When the suspended particle concentration of the recharge liquid were 50、100、200mg/L,the surface permeability coefficient dropped to 21%、13% and 4% of the initial respectively,This indicated that clogging of different levels occurred in the surface medium.Along with the increase of sand layer depth,the influence rate of the particle concentration was no longer distinct.In addition,external clogging occured in the case of small in-and-out water head difference.The permeability coefficient of surface layer declined to 7% of the initial with a water head difference of 19.25cm when the recharge ended;With larger water head difference,the clogging range and degree were greater,the permeability coefficient of 19~34cm sand layer was reduced to 60% of the initial with 48.64cm water head difference.
What problem does this paper attempt to address?