Identification and Determination of 5 -Hydroxymethyl- furfural in Angelica Injection

YIN deng-ke,DING Hong,FANG Shi-ping,YU Xin
2005-01-01
Abstract:Objective: Identification and quantitation of 5-Hydroxymethyl-furfural (HMF) in Angelica injection. Methods: Ethyl acetate extract of Angelica injection was analyzed with GC/MS, the gas chromatographic conditions was advanced as follows: Alltech AT~(TM-5) (30 m×0.2 mm×0.2μm) column,high purity helium was used as carries gas with flow rate at 1 mL·min~(-1); Injector temperature: 220℃; Column temperature: 70℃ keeping 1 min,from 70 ℃ to 200℃ (10℃· min~(-1)) , keeping for 1 min, then from 200℃ to 270℃ (20℃· min~(-1)) keeping for 5 min; MS detected with total ion monitoring. The MS of retention time of 8.06 min on GC is matched with reference standard HMF. It was demonstrated that HMF existed in Angelica Infection through GC/MS and HPLC methods with standard HMF. The condition of HPLC as follows: Agilent Zorbax C_(18) column (150 mm×2.1 mm×5μm) ,the mobile phase: methanol(B) , 1% acetic acid (A) , 10% B-90% A→90% A-10% B (25 min) , flow rate: 1 mL·min~(-1),detective wave length:320nm,column temperature:30℃ and the HPLC method for quantitation of HMF was established. Result: Angelica injection contains HMF and the HPLC method for quantitation of HMF in Angelica Injection is effective.
What problem does this paper attempt to address?