Validity Analysis of Sample Strain Measurement in Dynamic Tensile Experiment

TIAN Hong-wei,GUO Wei-guo
2008-01-01
Abstract:In order to evaluate the validity of specimen strain measurement,which is glued to Hopkinson loading bars,the dynamic tensile experiments were carried out using four types of fiber reinforced plastic with remarkable different strength and stiffness.Specimens were sandwiched and glued to the bars by epoxy resin before testing.The specimen strain was obtained respectively from the one-dimensional stress wave theory calculation of Hopkinson bar and the direct measurement by a strain gage.Results show that for CFRP materials with small deformation,the relative errors between these two methods are over 100%,while for GFRP and KFRP with larger failure strain,the relative strain errors of these two methods are less than 40%,which indicates that the calculated strain from the one-dimensional stress wave theory of Hopkinson bar is not accurate.In order to modify the error,one way is to establish a function between the calculated strain and the directly measured strain data through extensive experiment,therefore the valid sample strain can be obtained.The second way is to subtract the glue deformation and the specimen transition sections from the strain determined from waves in the bars based on the ABAQUS finite element analysis.The valid sample strain values can also be obtained.
What problem does this paper attempt to address?