Enhanced Phosphorus Removal in Membrane Bioreactor Combined with Electrocoagulation

Zhi-guang CUI,Shu-yuan LI,Jun-lin XIA,Tao XUE,Xia HUANG
DOI: https://doi.org/10.3321/j.issn:1000-4602.2009.07.001
2009-01-01
Abstract:Electrocoagulation/MBR(EC/MBR) process was used to enhance the removal of phosphorus from synthetic domestic wastewater.By controlling the electric current intensity and power-on time,the phosphorus removal rate can be maintained at above 95%,and the effluent TP concentration is less than 0.5 mg/L.Meanwhile,the removal rates of COD and ammonia nitrogen are about 90% and 95% respectively.The electrocoagulation can improve the sludge activity and decrease the sludge viscosity,the average sludge particle size and the organic matter concentration in the supernatant.These changes contribute to reducing membrane fouling and improving the long-term stability of the reactor.