HPLC Determination of the Content of Lutein Marigold Particles

WANG Rui,SUN De-ya,WANG Yan,LIU Xin
DOI: https://doi.org/10.3969/j.issn.1001-4721.2013.03.019
2013-01-01
Abstract:Ultrasound, reflux and soaking methods were used for separation of lutein marigold extract and then purified by liquid saponification its determination. The best method of separation and extraction was chosen。ODS C18column using filler( 416×250mm, 5μm), Column temperature at 30℃, flow at 1mL / min, sample 10μL, time: 22min, mobile phase A( acetonitrileBmethanol= 9:1):B( ethyl acetate). Samples using a gradient elution, 0~ 5min when B Mobile phase at 10%, 5~ 15min when B Mobile phase was set at 15%, 15~ 20min when B Mobile phase was 0%, the detection wavelength was at 450nm. Soaked by the lutein extraction yield can be seen as the extraction of lutein marigold particles effective experimental methods and soak 16h marigold lutein yield most. Lutein concentration and peak area, respectively 0.1~ 0.6mg / mL( r =0.999 7) showed good linearity. Standards and samples by liquid chromatogram determined by comparing the sample obtained after saponification of lutein. This experiment proved the best lutein extraction saponification experiments.
What problem does this paper attempt to address?