Photoplethysmography for Assessing Microcirculation in Hypertensive Patients After Taking Antihypertensive Drugs: A Review
Yanchun Hu,Anming Hu,Shenju Song
DOI: https://doi.org/10.2147/jmdh.s441440
2024-01-17
Journal of Multidisciplinary Healthcare
Abstract:Yanchun Hu, 1 Anming Hu, 2 Shenju Song 3 1 Department of Orthopaedics, the Fifth People's Hospital of Jinan, Jinan, People's Republic of China; 2 Taishan College, Shandong University, Jinan, People's Republic of China; 3 Department of Nursing, the Fifth People's Hospital of Jinan, Jinan, People's Republic of China Correspondence: Yanchun Hu, Department of Orthopaedics, the Fifth People's Hospital of Jinan, No. 24297 of Jingshi Road, Jinan, 250022, People's Republic of China, Tel +86 531 87198016, Email High blood pressure (BP) is a common disease and is associated with many chronic diseases. Measuring BP is essential for the treatment and management of many diseases, and therefore there is a growing need for a non-invasive, sleeveless and continuous BP monitoring device. With the development of technology, pulse waveform analysis using photoplethysmography (PPG) has become more feasible for evaluating BP. This study aimed to evaluate the changes of vascular elasticity and blood volume over time by using the characteristic parameters extracted by PPG. We reviewed the latest progress and literature on the observation of capillary network characteristics in hypertensive and non-hypertensive patients by PPG, the influence of different drugs on microcirculation characteristics in hypertensive patients with PPG, and further explored the key relationship between microcirculation and hypertension. We found that the PPG waveform produced by the fingertips of hypertensive patients is very different from that of healthy people, and the PPG waveform changes significantly during diastolic period after antihypertensive treatment. With the rapid development of medical technology, people can get more intuitive microcirculation image data, which provides beneficial help for the comprehensive understanding of hypertension. Keywords: capillary network, microcirculation, hypertension, PPG, arteriovenous anastomosis High blood pressure (BP) is a common disease. There is still uncertainty about the effectiveness of blood pressure drugs taken by people with high BP. 1,2 Sometimes, the condition has no apparent symptoms for patients insensitive to therapeutic drugs. It usually goes undetected unless a health professional regularly monitors BP. 3 Especially for those patients with refractory hypertension who are not detected in time, taking blood pressure medications, and remain at increased risk for mortality. Therefore, BP monitoring is essential in managing and treating hypertension. Because of the high branching, the capillary network has a substantially higher overall cross-sectional area. The capillaries may act as a "windkessel" to dampen the pulsations caused by the heart because of their low elastic modulus. This structural and functional feature also makes the pressure in the capillary network significantly lower than that in the arteriole. 4 As the smallest blood vessels, the blood flow in the capillaries is not smooth. 5,6 For example, red blood cells with a diameter of 7 μm must bend to flow through them. 7,8 When studying the hydrodynamic characteristics of the cardiovascular system, the basic flow equation is usually used, ie (the Poiseuille equation). But the Poiseuille equation is not accurate in measuring fluid resistance in complex elastic vessels, especially in a structure whose total cross-sectional area is wider in the middle and narrower at both ends. 9 Therefore, the analysis of the characteristics of microcirculation perfusion is of great significance for further understanding of peripheral resistance and hypertension, but the irrational application of the Poiseuille equation may affect the correct understanding of peripheral resistance and the essence of hypertension. The microvascular tissue bed may be monitored for changes in blood volume using the simple, affordable optical approach known as photoplethysmography (PPG). 10 Recently, it has been generally accepted that PPG components can provide valuable information about the cardiovascular system. 11,12 In this work, we summarized the characteristics of capillary PPG parameters in different subjects and discussed peak changes in patients with hypertension after applying nitroglycerin or urapidil. What's more, physiological and pathological information can be extracted by studying the characteristics of pulse wave signals. Microvascular measurement is currently a great challenge in clinical practice. Because the spatial structure of microvessels is non-uniform, high variations in perfusion over time can lead to inaccurate measurements. Therefore, the current research on microvascular imaging remains to be further developed. And the direction of microvascular imaging is diverse, and the correct technique can b -Abstract Truncated-
health care sciences & services