Resonance Characteristics of a Vibrated Fluidized Bed with a High Bed Hold-Up

Y Wang,TJ Wang,Y Yang,Y Jin
DOI: https://doi.org/10.1016/s0032-5910(02)00145-6
IF: 5.64
2002-01-01
Powder Technology
Abstract:The changes of vibration amplitude, bed expansion and forces on a fluidized bed from distributor with the applied vibration frequency are investigated at different gas velocities. The results show that there exist two resonance frequencies in the system of a vibrated fluidized bed (VFB), which result from the elastic properties of the vibration base and the fluidized bed, respectively. The change of the force on the fluidized bed with the vibration frequency is consistent with the change of the vibration amplitude. When the gas velocity and the vibration frequency reach certain values, the bed expansion ratio reaches its maximum. For vibration frequencies above this value, as the vibration frequency and amplitude change, the fluidization state is stable and the expansion ratio remains constant. This is an ideal stable operation region. The frequency at which the bed expands most rapidly to the maximum is defined as the minimum stable operation frequency, which is approximately the resonance frequency of the fluidized bed when the gas velocity is lower than 2.10 mm/s and approximately the resonance frequency of the vibration base when the gas velocity is above 2.10 mm/s.
What problem does this paper attempt to address?