[Mid-Term and Long-Term Clinical Effect of Micro-Perforating Trabecular Surgery with Amniotic Membrane Implants on Open Angle Glaucoma].

Haibo Jiang,Xiaobo Xia,Qilin Deng,Pingbao Wang
DOI: https://doi.org/10.3321/j.issn:1672-7347.2009.04.016
2009-01-01
Abstract:OBJECTIVE:To evaluate the mid-term and long-term clinical effect and complication of micro-perforating trabecular surgery (MPTS) with amniotic membrane implants on open angle glaucoma (OAG).METHODS:Thirty OAG patients (49 eyes) were treated with MPTS with amniotic membrane implants. Visual acuity, intraocular pressure, visual field, type of blebs, and complications were recorded pre-and post-operatively.RESULTS:Patients were followed up for 6~24(15.93+/-2.35) months. The mean IOPs before the operation and 24 months after the operation were (36.84+/-11.02) mmHg and (18.24+/-1.34) mmHg, respectively (P=0.000). The mean numbers of anti-glaucoma drugs used before and after the operation were (2.76+/-0.69) and (0.59+/-0.89), respectively (P<0.05). The global index of the early to moderate glaucomatous visual field loss was significantly improved postoperatively (P<0.05), and no significant difference was found in aggressive glaucoma pre- and postoperatively. Functional filter bleb was formed in 70.8% patients 24 months after the operation. The complete success rate and quality success rate were 75.5% (37/49) and 93.9% (46/49), respectively. There was no significant change in visual acuity pre- and postoperatively and no severe complication was found.CONCLUSION:Micro-perforating trabecular surgery with amniotic membrane implants is effective and safe for OAG, with reliable effect on lowering IOP in the mid-term and long-term.
What problem does this paper attempt to address?