Hydrolysis/Aerobic Double Fluidized Bed Process for Pepsi-cola Wastewater Treatment

Hai-zhen WU,Chen CAO,Chao-fei WU,Yuan REN,Jin-hua WU,Chao-hai WEI
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2010.22.017
2010-01-01
Abstract:For wastewater from production of Pepsi-cola concentrates with high concentration of organics and SS,unstable pH,high color and strong odor,the effluent of the original treatment system could not meet the specified standard.Under these circumstances,the combined process of triple loop aerobic biological fluidized bed and hydrolysis acidification was used to treat this wastewater.The designed capacity was 144 m3/d.This project has continuously operated for 3 years after commissioning.When the influent COD and BOD5 loading are 2.48 to 3.50 kg/(m3·d) and 1.45 to 1.88 kg/(m3·d),and the system total HRT is 20 h,the average removal rates of COD,BOD5,SS,NH+4-N and color are 95.5%,97.5%,91.4%,90.7% and 96.8% respectively.The effluent quality meets the first class criteria for newly constructed or extensively renovated projects in Wastewater Discharge Standard for Guangzhou City(DB 4437-90).The process data show that hydrolysis acidification increases the average value of B/C from 0.55 to 0.63.The aerobic double fluidized bed can effectively degrade organic matters,removing 91.6% of COD and 95.2% of BOD5,which proves that due to the structural functionality and combination with mass transfer and separation,the triple loop reactor can become a kind of efficient and practical technology for biological treatment of organic wastewater.