System Design of Digitally Controlled DC-DC Converter

熊付荣,吴金,赵霞,郑丽霞
DOI: https://doi.org/10.3969/j.issn.1681-1070.2009.11.008
2009-01-01
Abstract:Two methods adopting in system design of digitally controlled DC-DC Converter are presented. Based on the average model of power stage in S-zone,we can get the discrete model of this DC-DC system with 2~(nd) PID compensator,using classical Redesign-method.A new 3~(rd) compensator taking advantage of Direct-Digital method to improve load transient response is proposed.The Matlab/Simulink stimulation results are shown that the maximum overshooting voltage of 3~(rd) compensation system is around 160 mV and the steady time is about 30μs when load current changes from 500mA to 1A in 1μs,while 450mV and 110μs for 2~(nd) PID compensation system.At the same time,the maximum overshooting voltage of 3~(rd) compensation system is around 450mV and the steady time is about 45μs when input voltage changes from 3 to 5 in 1μs,while 610mV and 115μs for 2~(nd) PID compensation system.The load regulation and linear load capability of 3~(rd) compensation system is improved greatly compared to system using 2~(nd) PID compensators.
What problem does this paper attempt to address?