Comparative Research on Fault Detection Methods for Integrated Navigation System

LIU Guo-liang,ZHANG Ying-chun,QIANG Wen-yi,SUN Zeng-qi
DOI: https://doi.org/10.3969/j.issn.1671-7848.2006.02.007
2006-01-01
Abstract:The fault detection methods for integrated navigation systems are compared.The χ~2 test method and the judgment method of data change rate are presented,and a fault detection method based on fuzzy comprehensive evaluation is proposed.The method comprehensively judged all the measured data of each subsystem in order to determine states of the subsystems.At last,the above three methods are compared in an experiment on a GPS/INS integrated navigation system.The results of the experiment shows that the χ~2 test method is not sensitive to soft-faults,the judgment method of data change rate could not judge continuous faults,and the method of fuzzy comprehensive evaluation could judge all of faults by adjusting parameters properly for concrete integrated navigation systems.
What problem does this paper attempt to address?