Improvement and Experiment of the Portable Soil EC Detector

Chen Ling,Li Minzan,Zhao Yong
DOI: https://doi.org/10.3969/j.issn.1003-188X.2009.07.051
2009-01-01
Abstract:A portable soil electrical conductivity(EC) detector based on the electrical current-voltage four-electrode method was improved and its stability and repeatability were tested.The grey-brown alluvial soil in northern China was selected as the research object.The effects which water content and soil salinity had on the soil ECs were studied respectively.The experiments indicated that the improved detector performed well.The repeatability and precision of the detector were improved and the maximum relative error of the system was less than 4.4%.There was a linear correlation between soil ECs and soil water content in the range of 8%~30%(R2=0.9635).Also,Soil ECs varied linearly with soil salinity in the range of 0.1%~0.3%.When the soil salinity was higher than 0.3%,soil ECs remained the same.
What problem does this paper attempt to address?