Preparation and characterization of dual-modality molecular probes for imaging angiogenesis of gastric cancer
Xianping Liu,Kaichun Wu,Shuhui Liang,Mingyuan Gao,H. Yin,Xiao-wei Kang,Guangquan Wei,Ruirui Qiao
DOI: https://doi.org/10.3760/CMA.J.ISSN.1005-1201.2014.05.004
2014-05-01
Abstract:Objective: To develop an MR optical dual-modality probe targeting angiogenesis of gastric; cancer and to study its physical characteristics, in vitro cytotoxicity and magnetic effects of different pulse sequences on 3 T clinical MR scanner. Methods: We conjugated GXl-Cy5.5, a novel gastric cancer neo-vasculature targeted peptide labeled with Cy5.5, to the surface functionalized magnetic: nanoparticles according to different molecular weights (1:100, 1:500), resulting in dual-modality probe DPs, and DPs (named DPs). The hydrodynamic size and zeta potential of DPs and DPs were analyzed by nano-ZS. The human umbilical vein endothelial cells (HUVECs) and BGC-823 cells were treated with DPs for 24 h, and methyl thiazol tetrazolium (MTT) method was used to detect the survival rate of cells. DPs with different concentrations were scanned on different MR sequences, and then the relative signal intensity was observed. The absorbance of HUVECs and BGC823 cells treated with DPs of different concentration (0.00, 1.25, 2.50, 15.00, 50.00, 100.00 and 150.00 (xg/ml) were compared with single factor analysis of variance. Relative signal intensity of different MR sequences was compared using a paired Wilcoxon signed-rank test. Results: The dual-modality probe targeting angiogenesis of gastric cancer was successfully constructed. The hydrodynamic size of iron oxide nanoparticles, DPs and DPswas (35.23±0.07), (39.49±0.16) and (40.43±1.70) nm and the Zeta potential was (0.31±0.20), (-4.15±0.79) and (-10.51±2.37) mV. The coupled rates of DPs and DPs with polypeptide were 92% and 94% respectively. The absorbance of HUVECs and BGC823 cells treated with DPs of different concentrations were 0.76±0.04, 0.80±0.03, 0.79±0.05, 0.75±0.06, 0.74±0.05, 0.77±0.01, 0.71±0.04 and 0.38±0.04, 0.43±0.04, 0.41±0.03, 0.43±0.07, 0.44±0.04, 0.41±0.07 and 0.40±0.04, there was no statistical significance (F=0.94, 0.51; P≤0.05). The signal intensity increased first and then decreased following the increasing concentrations of DPs on TWI, especially on FSPGR TWI (Z=-3.294, P 10 μg/ml, the signal intensity on SSFSE TWI was significantly decreased compared to FSE TWI (Z=-2.023, P<0.05). Conclusions: DPs may be potential dual-modal probes for characterization of tumor angiogenesis by MR and optical imaging noninvasively, without causing significant effects on the cell activity in vitro, and SSFSE TWI may be the most sensitive sequence for DPs evaluation on MR.
Engineering,Medicine