Design of Three Phase Smart Meter Based on MAXQ3108 and DS8102

Xiao Qian,Mao Jianpin,Mao Jianxu,Ren Zhiren
DOI: https://doi.org/10.16526/j.cnki.11-4762/tp.2011.11.027
2011-01-01
Abstract:Almost all three-phase smart meter in the market used the current transformer as current sensor,and the smart meters of this kind measuring accuracy are universal vulnerable to external magnetic field interference at present,this paper introduced the MAXQ3108 + DS8102 solution of Maxim company,have designed a three-phase smart meter using manganin shunt as current sensor,solved the technical bottleneck that using manganin shunt sampling current each phase voltage,current signal and data acquisition MCU should keep electrical isolation,and illustrates the signal acquisition and measurement process.Prototype test results showed that the three-phase smart meter could effectively restrain the external magnetic field interference,active energy measurement precision meet 0.5S level technical requirements of IEC62053 standards.