Abstract:The Chiralpak AD-H (250 mm x 4. 6 mm, 5 mu m) column was used to establish an NP-HPLC method for the chiral separation of entecavir and its optical isomer. The composition of mobile phase and its acidity were optimized to reach better column efficiency and resolution. The final chromatographic conditions were established as follows: n-hexane: isopropyl alcohol: ethanol: trifluoroacetic acid: triethylamine (70:12:18: 0.05:0.05). The detection wavelength was 261 nm and the flow rate was 0.50 mL/min. The resolution of entecavir and its optical isomer was more than 4.2. The linear range was 0.25-4 mg/L. The limit of detection (LOD) of optical isomer was 0.12 mg/L. The relative standard deviations (RSD) of intra- and inter-day precisions were less than 4.0% (n = 3). According to calibration curves by general external standard method, the recoveries of the optical isomer were in the range of 98.2%-110.4% RSD < 3%. According to calibration curves by standard addition method, the recoveries of the optical isomer were in the range of 87.0% - 100.2%, RSD < 3%. The limit of the optical isomer was determined using "main component self-compare with calibration factor" under the chromatographic conditions established. It was shown that the established HPLC method was reliable, simple and was applicable to the purity determination of entecavir.