Selective detection of tryptophan using multiwall carbon nanotube modified glassy carbon electrode

Zheng Yanqiong,Yang Changzhu,Zhang Jingdong,Pu Wenhong
DOI: https://doi.org/10.3321/j.issn:1671-4512.2008.05.035
2008-01-01
Abstract:Electrochemical behaviors of tryptophan(Trp) and tyrosine(Tyr) on multi-walled carbon nanotubes modified glassy carbon(MWNTs/GC) electrode were studied.The result demonstrates that MWNTs/GC electrode greatly catalyzed the oxidation of Trp and Tyr compared with glassy carbon electrode.The ratio of signal and background current indicates that the modified electrode catalyzes more greatly Trp than Tyr.pH test result demonstrates that Trp and Tyr could be separated in 1.0mol/L H2SO4 solution,which provides the possibility of selective detection Trp in the presence of Tyr.In the mixture,the peak current of Trp was linearly proportional to the concentration in the range from 7.50×10-6mol/L to 2.00×10-4mol/L,the detection limit was 3.29×10-6mol/L(SPN is 3).The method was applied to the detection of Trp in 17AA compound amino acid injection,the recovery is over 97%.
What problem does this paper attempt to address?