Latest research and development of twin-straight tube Coriolis mass flowmeters

Tao Wang,Yousif Hussain
DOI: https://doi.org/10.1108/02602280710723460
2013-01-01
Sensor Review
Abstract:Purpose - The paper aims to theoretically predict sensor signals and calibration factors for twin-straight tube Coriolis flowmeters. It also aims to determine an optimal flow path to minimize pressure loss. Design/methodology/approach - Two major aspects involved in the latest research and development of a series of twin-straight tube Coriolis mass flowmeters are presented. Firstly, the theoretical method adopted for the concept design to predict sensor signals and calibration factors is given. This is essentially a finite element method using the fluid structure interaction theory based on a Timoshenko beam coupled with one-dimensional flow. Secondly, detailed design using computational fluid dynamics is described to optimise pressure loss. Finally, experimental results from testing a prototype meter are given and compared with the numerical results. Findings - Finds that sensor signals and calibration factors can be predicted with the presented method. Also finds that pressure loss can be minimized with an optimized flow splitter. Practical implications - Comparison between experiments and theoretical results shows agreement and indicates the effectiveness of computer-aided engineering at an early development stage of Coriolis mass flow sensors. Originality/value - Provide a theoretical model to predict sensor signals and calibration factors for Coriolis mass flowmeters. Introduce an optimized splitter shape for a twin tube configuration.
What problem does this paper attempt to address?