Nondestructive Quantification of the Soluble-Solids Content and the Available Acidity of Apples by Fourier-Transform Near-Infrared Spectroscopy.

YB Ying,YD Liu,Y Tao
DOI: https://doi.org/10.1364/ao.44.005224
IF: 1.9
2005-01-01
Applied Optics
Abstract:This research evaluated the feasibility of using Fourier-transform near-infrared (FT-NIR) spectroscopy to quantify the soluble-solids content (SSC) and the available acidity (VA) in intact apples. Partial least-squares calibration models, obtained from several preprocessing techniques (smoothing, derivative, etc.) in several wave-number ranges were compared. The best models were obtained with the high coefficient determination (r2) 0.940 for the SSC and a moderate r2 of 0.801 for the VA, root-mean-square errors of prediction of 0.272% and 0.053%, and root-mean-square errors of calibration of 0.261% and 0.046%, respectively. The results indicate that the FT-NIR spectroscopy yields good predictions of the SSC and also showed the feasibility of using it to predict the VA of apples.