INDOOR AMMONIA POLLUTION IN NEW BLANK HOUSES IN LANZHOU
CHEN Yu-juan,LIU Xing-rong,HUANG Min
DOI: https://doi.org/10.3969/j.issn.1003-8507.2007.14.034
2007-01-01
Abstract:[Objective]To measure the concentration of indoor ammonia in new blank houses in Lanzhou and understand the status of indoor ammonia pollution,find out the source of indoor ammonia,explore the effects of indoor temperature,relative humidity and the built time of the houses on the concentratron of indoor ammonia.[Methods]40 new blank houses in Lanzhou with the built time of 6 months or 12 months were selected.Indoor ammonia was detected by RT-3 type ammonia monitor.[Results]The mean concentration of indoor ammonia was 0.147 mg/m3.Out of the 40 new blank houses,8(20%)of them exceeded the national standard of 0.20 mg/m3.The percentage of new blank houses with an ammonia concentration in the reference levels of ≤0.10,0.10-0.20 and ﹥0.20 mg/m3 was 37.5%,42.5% and 20.0% respectively.Significant differences in indoor ammonia concentration were found between 6-month blank houses and 12-month houses(P﹤0.05).Ammonia concentration increased with the increase of indoor temperature and the decrease of relative humidity.[Conclusions]The concrete admixtures such as antifreezer in wall body are probably the chief source of indoor ammonia.Temperature and relative humidity affect the level of indoor ammonia.Regular ventilation is the most effective approach to eliminate indoor ammonia.