PIV monitoring of flow fields in folded plate flocculators

Yang Xiaolin,Yang Kaiming,Zhang Bingbin,Deng Wanquan
DOI: https://doi.org/10.3969/j.issn.1001-3865.2008.12.012
2008-01-01
Abstract:The complex flow fields in a lab scale folded plate flocculator were monitored and measured using the particle image velocimetry(PIV)technology.The mechanisms of flow characteristics affecting flocculation in the zoom unit and the turning unit of folded plate were analyzed.Results of coagulation experiments show tiat the flocculation effectiveness was dependent on the vortex flow field of the folded plate flocculator and that the combination of 90° opposite folded plate and 90° same wave folded plate perform the best with 97.7% reduction in turbidity(from 5.000 to 0.117 NTU).Such findings are useful theoretical basis for design of cost effective folded plate flocculators.