In Vitro Corneal Retention of Betaxolol Hydrochloride Cationic Liposomal In-situ Gels

Li Tian,He Wen,Tan Yi,Wang Jun
DOI: https://doi.org/10.3969/j.issn.1008-049X.2013.08.002
2013-01-01
Abstract:Objective:To study the in vitro corneal retention and irritation of betaxolol hydrochloride('ationic liposomal in-silu gels (BHCL-ISG).Method:Betaxolol hydrochloride liposomes(BHL) were prepared by a reverse phase evaporation method followed by N-trimelhyl chitosan(TMC60) coating to obtain the cationic liposomes(BHCL).The ISG was prepared by mixing BHCL with the temperature -sensitive base consisting of poloxamer 407 and 188.The in vitro corneal retention of BHCL-ISG was evaluated by sessile bubble and captive bubble technique.The ocular irritation was performed by the Draize method.Result:The morphology of BHCL-ISG was spherical with uniform size and positive Zeta potential.Compared with that of BHL and BHL-ISG,the contact angle between BHCL-ISG and in vitro cornea was the largest,while the corneal retention of BHCL-ISG was significantly prolonged(P<0.05) with promising ocular compatibility.Conclusion:BHCL-ISG shows prolonged corneal retention and good ocular compatibility.
What problem does this paper attempt to address?