Evaluation of cerebral haemorrhage SWI in by at 3.0 T MRI
JI Ming,YE Chun-tao,MIAO Hua-dong,ZHU Zhen-fang
2008-01-01
Abstract:Objective To evaluate the application value of susceptibility weighted imaging(SWI) at 3.0 Tesla(T) MRI in patients with cerebral haemorrhage.Methods Thirty three patients(average age: 68.5±2.6) involved in this study were divided to two groups: 6 for acute course and 27 for chronic course.All cases underwent SWI,T2W,FLAIR and T1W scan with 3.0T MR scanner(SIEMENS).For each sequence used,the data of the ratio of focus displayed,ratio of haemorrhage showed,size of bleeding,branches of cerebral vein revealed and image quality were evaluated and analyzed statistically.Results Ratio of lacunar cerebral infarction: SWI,48%;T2W,100%;FLAIR,100%;T1W,71%.Ratio of cerebral internal bleeding: SWI,100%;T2W,50%;FLAIR,50%;T1W,35%.Abnormality of cortex vein branches: SWI,10 and 0 for the rest sequences.Of 20 cases,the maximum haemorrhage sizes were(mean): SWI,320mm2;T2W,220mm2;FLAIR,250mm2;T1W,120mm2.The acquired SWI images were good(97%).x2 was performed using SPSS for statistical analysis,which showed: the ratio of SWI for cerebral haemorrhage was the highest(p<0.05,compared with T2W,FLAIR and T1W.Conclusion SWI is a potent examination for cerebral bleeding displaying due to the higher sensitivity compared with the other sequences.The diagnostic accuracy will be improved with SWI combined with general scanning.