Mechanism of removal of high concentration ammonia and kinetics of microbial growth
Ying CHEN,Jin GUO,Wei LIU,Xiao-jun XU,Shu-li LIU
DOI: https://doi.org/10.3969/j.issn.1005-9954.2017.12.001
2017-01-01
Chemical engineering
Abstract:Simulating the practical engineering application process,under the optimal experimental condihons of gas flow rate 700 L/h,gas residence time 1.2 min,circulating water flow 85 L/(m3 · h),mass concentration of COD(Cr)in the circulating water 40 mg/L,pH =8.5,n (N) ∶ n (P) =5 ∶ 1,and mass concentration of NaCl 400 mg/L,the removal efficiency of high concentration NH3 with the zeolite as the filler was studied by changing the inlet concentration of NH3.The maximum inlet concentration of the device could reach 925 mg/m3.Microfauna on microbial film in filter under different NH3 load was authenticated and analysed.When the NH3 load is less than 1 g / (L · d),arcellas are the most,which means nitrobacterium growing well.When the NH3 load is greater than 1 g/(L · d),arcellas decreases rapidly and shaking worms increases rapidly,which means rate of nitrification reducing and nitrobacterium growing slowly.According to the logic equation,the logarithm of the biofilm quantity of nitrifying bacteria in the biofilm growth period is linear with time,and the slopeμ0 =0.003 9 t-1.The experimental results provide reliable and favorable data basis for the design and debugging of the equipment in practical engineering.