Mass transfer characteristics of hemoglobin solution in ultrafiltration process
Ke Xiao,Feng Liu,Wei Gao,Xiang Wang,Ying Wang
DOI: https://doi.org/10.3969/j.issn.1673-8225.2011.25.004
2011-01-01
Abstract:BACKGROUND: Ultrafiltration membrane has the characteristics of little destruction of the natural conformation of the protein and high recovery, which has been used in the isolation and purification of protein. OBJECTIVE: To optimize utrafiltration of hemoglobin by using of the mass transfer model in order to isolate highly purified hemoglobin. METHODS: Penetration flux, concentration of solution and the relationship between pressure and flux of enrichment hemoglobin solution in the process of ultrafiltration were studied by membrane ultrafiltration isolation and purification methods. Membrane resistance and concentration polarization resistance were quantitatively described and the mass transfer model was established. RESULTS AND CONCLUSION: {circled digit one}For the solution concentration of 1.69, 2.07, 2.66, 3.66 g/L, the ultrafiltration flux was 1.927 5, 1.875 0, 1.812 5, 1.750 0 L/(m 2•h) respectively at the pressure of 0.04 MPa, 12 °C; For the different pressure: 0.02, 0.03, 0.04, 0.05, 0.06 MPa, the ultrafiltration flux was 0.165, 0.245, 0.325, 0.400, 0.475 L/(m 2•h) respectively with the same time; {circled digit three}The membrane resistance was 0.118 2, and the pressure coefficient was 0.128. However, the gel layer was gradually formed with the increase of protein concentration; it was hard to concentrate the hemoglobin when the concentration was equal to the gel concentration. The gel concentration C g was 18.82 g/L, and the ultrafiltration mass transfer coefficient k was 0.700 8.