Process Investigation on Activated Sludge In-Series System Treating Pharmaceutical Wastewater

CAI Meng-meng,ZHAO Qing-liang,LIU Zhi-gang,Chua Hong
DOI: https://doi.org/10.3321/j.issn:0367-6234.2007.04.016
2007-01-01
Abstract:A lab-scale study on completely-mixed activated sludge aeration tank in-series(CMAS in-series) treating pharmaceutical wastewater from a Harbin pharmacy plant was conducted to optimize the practical full-scale plant operation parameters and to explore the removal of various pollutants.In CMAS in-series system,such operational conditions like F/M=0.1-0.2 or 0.8-1.5 gCOD/(gMLSS·d),SRT=8-10 d,ρ(DO)=1-3 mg/L and temperature 27-34 ℃ benefited sludge settling ability and obtained the removal rate of COD and TSS over 90% and 95%,respectively.Specific oxygen uptake rate of SOURavg.=49.5 mgO2/(gMLSS·h) indicated good sludge activity in the aeration tanks of CMAS in-series.Increasing the tank number of CMAS in-series system favored sludge settling ability under the same HRT.Bio-degradation of COD in this system followed a mathematical model of ρ(CODe)=ρ(COD0)×e-at.Practical project operation performance from the simulation results showed that the system was effective and steady,and the effluent met the first level criteria of the Integrated Wastewater Discharge Standard(GB8978-1996).