The Light Illuminance Level in Waiting Rooms of a Railway Station

马卫武,刘伟,李立清,刘小燕,马泽谦
DOI: https://doi.org/10.3321/j.issn:1000-7857.2009.14.017
2009-01-01
Abstract:The illumination in the waiting room at the railway station of Harbin,Beijing,Shanghai and Changsha has been measured.The research started with human comfort.Based on this,the questionnaire of passenger's lighting comfort has been carried out.With the statistical result,passenger's lighting comfort has been analyzed.The fuzzy mathematics method is widely used in each field of science.The annoying threshold of lighting environment in the waiting room has been calculated with the help of this method.The annoying threshold is a kind of measurement that reflects passenger's lighting comfort.With the Ridit method,the illumination value of standard group and reference group has been obtained.Based on the result,the comfort range of illumination has been calculated.According to this illumination interval,the illumination standard of railway station waiting room has been established.Result shows that the annoying threshold in waiting room is 92.3 lx.The standard illumination value of the waiting room is from 113.6 to 73.2 lx.Considering the illumination of 80 lx is mostly close to the mean Ridit value of 0.5.So it could be taken as the illumination standard in the waiting room at the railway station.The illumination of 80 lx could meet passenger's comfort demands.
What problem does this paper attempt to address?