An electrochemical immunosensing method based on silver nanoparticles
Nan Hao,Hui Li,Yitao long,Lei Zhang,Xirui Zhao,Danke Xu,Hong-Yuan Chen
DOI: https://doi.org/10.1016/j.jelechem.2011.01.029
IF: 4.598
2011-01-01
Journal of Electroanalytical Chemistry
Abstract:Research highlights ► In this article an electrochemically direct stripping approach based on silver nanoparticles (AgNPs) labeled with antibody was proposed. ► Human IgG was used as a model protein sample to be immobilized on a screen printed electrode and the goat-anti-human IgG labeled AgNPs was added onto the surface of the SPE. ► With the oxidation of AgNPs labels, the concentration of hIgG could be assayed directly and calculated. ► The dynamic concentration was in the range of 1–1000 ng/mL and the detection limit was 0.4 ng/mL (S/N = 3). Abstract In this article, an electrochemically direct stripping approach based on silver nanoparticles (AgNPs) labeled with antibody was proposed. To prepare AgNPs labels, glutathione (GSH) was chemically absorbed on the surface of AgNPs through its free thiol groups. Glutaraldehyde was used as a coupling reagent, its two aldehyde groups reacted with the amino group of GSH absorbed on the AgNPs surfaces and the amino groups of antibodies, respectively. The resulting labeled electrochemical active nanoparticles could recognize the proteins specifically via the immobilized antibody. To prove the electrochemical property of labeled AgNPs, human IgG was used as a model protein sample to be immobilized on a screen printed electrode (SPE) and the goat-anti-human IgG labeled AgNPs was added onto the surface of the SPE, followed by differential pulse voltammetric (DPV) method. With the oxidation of AgNPs labels coupled on the electrodes, the concentration of hIgG could be assayed directly and calculated. The dynamic concentration was in the range of 1–1000 ng/mL and the detection limit was 0.4 ng/mL ( S / N = 3). In addition, the presented method was also compared to indirect electrochemical stripping detection by dissolving AgNPs labels with nitric acids and the results showed advantages such as lower detection limit, rapidity and simplicity. Keywords Silver nanoparticles Protein assay Immunosensor Electroanalysis 1 Introduction With the coming of proteomics and post-genomics, more effective and sensitive analytical methods to assay proteins are being demanded for the research on protein function due to many important proteins are present at ultra-low levels [1,2] . In addition, it is essential to develop sensitive, selective, and rapid methods for the diagnosis of disease in early stages and drug discovery since most of biomarkers belong to proteins. Immunosensors have been widely used in the detection of proteins [3] . Among them, electrochemical immunosensors based on nanoparticles have attracted considerable interest in recent years because of their high sensitivity, low-cost and inherent miniaturization [4] . Nanoparticles with diameter of 1–100 nm possess many unique properties such as catalysis, high ratios of surface area to volume, and effective acceleration of electron transfer [5] . Taking advantage of their molecular recognizing property by labeled antibodies, nanoparticles have also been used as bioassay labels for electrochemical Immunosensors. With such recognizing reaction between labeled nanoparticles and analytes, the quantification of target molecules can be achieved by the electrochemical detection of nanoparticles [6] . Liu et al. reported a multi-antigen sandwich immunoassay protocol for the simultaneous measurements of proteins by applying different quantum dots (CdS, ZnS, PbS) [7] . Three encoding nanoparticles have thus been used to differentiate the signals of three kinds of protein targets in connection with a sandwich immunoassay and stripping voltammetry of the corresponding metals. Each biorecognition event yielded a distinct voltammetric peak, whose position and area reflected the identity and level of the targets, respectively. For metal particles, many works have been reported on the application of gold nanoparticles in biosensors [8,9] . Dequaire et al. developed an electrochemical immunoassay by using a colloidal gold label [10] , in which the colloidal gold labeled secondary antibody was coupled on the polystyrene microwells through sandwich reaction and then bromine-bromide solution was pipetted into the microwells to dissolve gold nanoparticles. The solution containing gold (III) ion was transferred to a disposable SPE and determined on concentration as low as 3 × 10 −12 M. Silver nanoparticles are less popular than gold nanoparticles in the field of biosensors due to their limited stability. In fact, AgNPs have own advantages such as the easy dissolution of silver without poisonous reagent like Br 2 as well as better electrochemical properties. The application of AgNPs in biosensors focused on DNA analysis. Cai et al. described an electrochemical DNA hybridization detection assay based on the hybridization of the target DNA with the silver nanoparticle–oligonucleotide DNA probes [11] . Wang et al. exploited the DNA-induced generation of metal clusters for developing an electrical biosensing method [12] . Szymanski et al. reported the first immunoassay utilizing silver nanoparticles for protein detection in 2010, in which silver colloid aggregates can be transferred from 96-well Plate onto SPEs and electrochemically assayed with detection limit of 3 ng/mL [13] . The sensitivity of metalloimmunoassays can be enhanced by deposition of metal on the surface of nanoparticles, which lead to generation of more metal ions for amplifying the signal. The metal that have been reported to amplify signal include gold [14] , silver [15,16] , copper [17] . Another process called biometallization has also been reported, in which metallization is catalyzed by an enzyme [18] . More recently, DNA oligomer functionalized AgNP aggregates has successfully been assayed on DNA arrayed gold electrodes reported by our research group [19] , in which AgNPs labels could be directly oxidized and produce current signals. Compared to indirect assay approaches, this method has more advantages such as rapidity, simplicity and sensitivity. In this paper, we developed an electrochemical detection approach to assay micro-volume protein by using AgNPs labels. A new modification method to couple silver nanoparticles with antibody covalently was presented and the resulting antibody labeled AgNPs could be used to directly assay the protein samples immobilized on screen printed electrodes (SPEs). Compared to indirect electrical detection method of dissolving AgNPs with nitric acids, the presented method exhibits its simplicity, rapidity and lower detection limit. 2 Experimental section 2.1 Apparatus CHI660 electrochemical workstation (CHI Instruments Inc., USA) was used to carry out differential pulse voltammetry. UV–Vis spectra were performed on UV-3600 spectrophotometer (Shimadzu, Japan). Transmission Electron Microscope (JEM-200CX, Japan) was used for collecting TEM images. Screen printed electrodes (Three-electrode devices) were mass manufactured by a screen-printing process using an AT-25P machine (ATMA CHAMP ENT. Corp.) according to the report previously [20] . Briefly, the circular working electrode and the ring-shaped counter electrode were prepared with carbon ink, and the reference electrode was prepared with the silver–silver chloride ink. The SPCE was first washed with distilled water and dried by stream. SPE was then pre-activated in a 0.1 M PBS (pH 6.0) containing 0.1 M KCl by applying an anodic potential of 1.9 V (vs. Ag/AgCl) for 120 s. 2.2 Materials Goat anti-human IgG (GAH-IgG) antibody, human IgG antigen and bovine serum albumin (BSA) were purchased from Bioss (Beijing, China). Reduced glutathione (Biosharp, Japan), glutaraldehyde (25%, National Medicines, China), NaBH 4 , AgNO 3 and other reagents were commercially available and used without further purification. The buffers include 0.1 M phosphate-buffered saline (PBS, pH 7.4), 0.01 M PBS, PBST, PBN. PBST was PBS (0.1 M, pH 7.4) buffer containing 0.05% (w/v) Tween 20. PBN was prepared by adding 8.5 g NaNO 3 to 1 L 0.01 M PBS (pH 7.4). All double distilled water used for all throughout experiments. 2.3 Preparation of silver nanoparticles Silver nanoparticles were prepared by the method reported previously [19] . Briefly, 10 mL aqueous solution of 2 mM AgNO 3 was added dropwise to NaBH 4 (40 mL, 3 mM) with continuous stirring in a conical flask held in an ice bath. At the end of this step, the flask was removed from the ice bath and the mixture was continuously stirred for an additional 30 min. 2.4 Preparation of antibody-AgNPs conjugates Add 20 μL GSH solution (0.1 mg/mL) to silver colloid (1 mL). After the incubation for 1 h at room temperature, 117 μL PBS (0.1 M) was added to this solution and incubated for another 1 h. Then the resulting solution was centrifuged at 15,000 rpm for 3 times (15 min each time) to remove excess GSH. The sediment was resuspended in PBS solution (0.01 M). Ten microliters of goat anti-human IgG (0.1 mg/mL) and 10 μL diluted glutaraldehyde aqueous solution (obtained by diluting 1.5 mL 25% glutaraldehyde solution into 10 mL) were mixed with GSH–AgNPs. The resulting mixture was incubated at 37 °C for 1 h, and then centrifuged for 3 times to remove free goat anti-human IgG and glutaraldehyde. The sediment was resuspended in 0.01 M PBS and stored at 4 °C. 2.5 Electrochemical measurement for protein sample by SPEs IgG (8 μL) of different concentrations including 0, 1 ng/mL, 10 ng/mL, 100 ng/mL, 1000 ng/mL, which were prepared by 0.1 M PBS (containing 1.0 mg/mL BSA), were added on disposable SPEs and incubated at 4 °C overnight. After the immobilization of IgG, SPEs were rinsed with PBST twice. Then 8 μL Antibody-AgNPs Conjugates were added and incubated at 37 °C for 30 min. After being rinsed with PBST for 3 times and PBN for once, differential pulse voltammetry was performed from −0.2 V to +0.3 V using an electrochemical workstation (CHI 660) with a pretreatment step (+0.8 V for 30 s and −0.8 V for 15 s). For indirect detection experiment, 20 μL HNO 3 (0.1 M) was first added on SPEs and incubated for 0.5 h to fully dissolve AgNPs. The resulting HNO 3 solution containing released silver ions was detected by differential pulse voltammetry with the same parameters as shown above. 3 Results and discussion 3.1 Preparation of antibody-AgNPs conjugates Functionalization of silver nanoparticles is similar to that of gold nanoparticles. Silver nanoparticles reduced from metal ions could be stabilized by anionic ligands and negatively charged. In this case, the adsorption of proteins to nanoparticles would be achieved by adjusting pH to make proteins positively charged [13,21,22] . However, physically adsorbed biomolecules are readily lost from the surface, and adsorbed proteins are often prone to be denaturized and thereby lose their biocatalytic or biorecognition activities [23] . In our work, glutathione was used as a coupling reagent to modify AgNPs via molecular self-assembly between mercapto group and silver surface. The UV–Vis spectrum of the modified and unmodified silver colloid is shown in Fig. 1 . It can be found that glutathione dramatically enhanced the stability of AgNPs to aqueous solution of sodium chloride. Compared to GSH–modified AgNPs, the absorbance of unmodified AgNPs solution decreased with adding NaCl (7 μL, 2 M). In fact, when 14 μL NaCl solution was added, the color of AgNPs solution changed to nearly colorless immediately. Thus, the results suggested that glutathione could not only provide amino groups but also improve the stability of AgNPs. The influence of GAH-IgG concentrations on analytical performance was also investigated. The AgNPs modified with 0.1 mg/mL GAH-IgG produced stronger signal than those modified with 0.01 mg/mL or 1 mg/mL antibody, respectively. It is understandable that lower concentration of antibody in the modification reaction would lead to lower coverage because part of AgNPs does not attach biorecognizing molecules. However, it is unexpected that the AgNPs labeled with higher concentration antibody could not produce greater current signal (the current decreased to 50%, data not be shown here). It can be calculated [24] that the ratio of GAH-IgG (67 nM) to AgNPs (1.6 nM) was 40 to 1 when 1 mg/mL (67 nM) antibody was introduced. Based on the sizes of IgG (10 nm) antibody [25] and AgNPs (20 nm), the higher antibody concentration may result in an entirely coverage of antibody molecules on the surface of AgNPs. In this case, the AgNPs modified with antibody could not be oxidized directly on the electrodes. Thus, the higher concentration could lead to the lower electric conductivity and lower current signals. Thus, the concentration of 0.1 mg/mL GAH-IgG was employed to prepare following antibody modification of AgNPs. Wu et al. reported a glutathione-assisted synthesis of silver nanoparticles and their application in suppressing the proliferation of human leukemic K562 cells [26] , in which 6–11 nm silver nanoparticles obtained were difficult to separate by centrifuge due to their small sizes. The morphology of prepared silver nanoparticles and antibody modified silver nanoparticles was further characterized by TEM. It can be found from Fig. 2 that the average diameters of both kinds of the AgNPs were around 20 nm. It indicates that the sizes have not significant difference between the unmodified and modified AgNPs. In fact, the presented method could be easier to separate and purify the modified nanoparticles. 3.2 Development of direct electrochemical stripping detection strategy Screen printing technology has widely been used for large-scale fabrication of disposable biosensors with several advantages such as low cost, versatility, and miniaturization [27] . Depend on van der Waals force between biomolecules and solid support surface, physical adsorption is often used to immobilize protein molecules on SPEs due to its simplicity and reproducibility. In our experiments, micro-volume Human IgG sample (8 μL) was transferred to SPEs and the electrochemical detection strategy is illustrated in Fig. 3 . The goat-anti-Human IgG labeled AgNPs recognizes the IgG molecules immobilized on the SPEs. After the rinse, the AgNPs were bound on the electrodes surface specifically and oxidized to silver ions upon applying DPV measurement. Compared to DNA immobilized AgNPs, protein modified AgNPs lead to greater hinder to electric conductivity because of larger molecular structure. In our primary experiments, direct DPV method reported previously [19] was employed to assay GAH-IgG–AgNPs coupled on the SPEs. However, lower current signals were detected on the protein modified SPEs. To enlarge current signals, a pretreatment step was developed before applying DPV measurement with a positive potential of +0.8 V vs. Ag/AgCl reference electrodes. AgNPs could be oxidized to silver ions and then electrochemically deposited on SPEs by applying a negative potential of −0.8 V. In this case, the silver ions could permeate into the electrode surface and produce amplified detectable current signals. This phenomenon was similar to the reported work previously [13] . Several experimental parameters including reaction time, the concentration of AgNPs and the concentration of GAH-IgG were optimized. Fig. 4 a shows that the current signals are dependent on the reaction time. When lengthened time from 15 min to 30 min, signal increased about 25%. With further lengthening reaction time, peak currents reached to a plateau. It suggested that the immunoreaction between human IgG and GAH-IgG on SPEs could be accomplished within 0.5 h. In addition, the effect of the variation of GAH-IgG concentration was also observed. It is shown in Fig. 4 b that the signals significantly decreased with the dilution of GAH-IgG silver nanoparticles. As a result, the original modified silver nanoparticles were used for the following experiments without dilution. 3.3 Analytical performance Most of electrochemical detection reports [28] based on AgNPs labels used indirect stripping method, i.e. AgNPs have to be dissolved by the addition of nitric acid before carrying out electrochemical assay. To compare with the presented method, indirect electrochemical stripping method was also attempted to assay 1 ng/mL human IgG by using the same AgNPs labels and dissolving with 0.1 M HNO 3 before the electrochemical detection. The results showed that the peak current was 1.1 × 10 −6 A with a background current of 0.8 × 10 −6 A ( Fig. 5 ), the ratio of current signal to background was 1.4. On the other hand, the presented method produced the current of 1 ng/mL is 0.3 × 10 −6 A with a background noise of 0.1 × 10 −6 A, the ratio of current signal to background was three ( Fig. 6 ). Although the dissolution step brought stronger signals for both the target and the noise, it made little contribute to low detection limit. To explore analytical performance of this electrochemical immunological assay, calibration curve was studied in detail. Fig. 6 shows a serial of differential pulse voltammgrams, corresponding to 1 ng/mL, 10 ng/mL, 100 ng/mL and 1000 ng/mL human IgG solution respectively. It can be observed that the peak current of silver nanoparticles is proportional to the concentration of human IgG. Thus, the dynamic concentration ( Fig. 7 ) was in the range of 1–1000 ng/mL. When the ratio of signal to noise was 3, the detection limit of this method was found to be 0.4 ng/mL. Compared to the classical electrochemical stripping method, our presented method can be exempted from the tedious oxidative dissolution of the AgNPs by the use of harmful reagents. Direct oxidation measurement can also be applied to multiplexed target detection and make the assay rapidity. Compared to the reported immunoassay method based on silver nanoparticles [13] , present current method could provide a lower detection limit with fewer steps. Thus, direct electrochemical stripping method based on AgNPs could provide more sensitive, rapid and simple analytical procedure. 4 Conclusion Based on the prepared AgNPs labels, a simple, low-cost electrochemical immunosensing method was developed and could provide a detection limit of 0.4 ng/mL. Compared to indirect electrochemical stripping method, the tedious oxidative dissolution or the use of harmful reagents to dissolve AgNPs could be exempted from this immunosensing method. As a result, the combination of silver nanoparticles and electrochemical detection method provides a sensitive and convenient approach to assay micro-volume protein samples. Acknowledgments The authors acknowledge financial support of National Natural Foundation of China (Grant Nos. 20975050 and 20775033), The National Science Funds for Creative Research Groups (No. 20821063) and National Basic Research Program of China (973 Program No. 2007CB936404). References [1] J. Wang Electroanal. 19 2007 769 776 [2] H. Zhang Q. Zhao X.F. Li X. Chris Le Analyst 132 2007 724 737 [3] H. Chen C. Jiang C. Yu S. Zhang B. Liu J. Kong Biosens. Bioelectron. 24 2009 3399 3411 [4] G. Liu Y. Lin Talanta 74 2007 308 317 [5] S. Guo S. Dong Trends Anal. Chem. 28 2009 96 109 [6] M. Pumera S. Sánchez I. Ichinose J. Tang Sens. Actuat. B-Chem. 123 2007 1195 1205 [7] G. Liu J. Wang J. Kim M.R. Jan G.E. Collins Anal. Chem. 76 2004 7126 7130 [8] J.M. Pingarrón P. Yáñez-Sedeño A.G. lez-Cortés Electrochim. Acta 53 2008 5848 5866 [9] W.R. Glomm J. Disper. Sci. Technol. 26 2005 389 414 [10] M. Dequaire C. Degrand B. Limoges Anal. Chem. 72 2000 5521 5528 [11] H. Cai Y. Xu N. Zhu P. He Y. Fang Analyst 127 2002 803 808 [12] J. Wang O. Rincón R. Polsky E. Dominguez Electrochem. Commun. 5 2003 83 86 [13] M. Szymanski A.P.F. Turner R. Porter Electroanal. 22 2010 191 198 [14] J. Wang D.K. Xu A.N. Kawde R. Polsky Anal. Chem. 73 2001 5576 5581 [15] Y.-H. Bai J.-Y. Li J.-J. Xu H.-Y. Chen Analyst 135 2010 1672 1679 [16] C.H. Yeh H.H. Huang T.C. Chang H.P. Lin Y.C. Lin Biosens. Bioelectron. 24 2009 1661 1666 [17] X. Mao J. Jiang Y. Luo G. Shen R. Yu Talanta 73 2007 420 424 [18] Y. Luo X. Mao Z.F. Peng J.H. Jiang G.L. Shen R.Q. Yu Talanta 74 2008 1642 1648 [19] H. Li Z. Sun W. Zhong N. Hao D. Xu H.Y. Chen Anal. Chem. 82 2010 5477 5483 [20] L. Zhang D.W. Li W. Song L. Shi Y. Li Y.T. Long IEEE Sensors J. 10 2010 1583 1588 [21] C.H. Yeh W.T. Chena H.P. Lin T.C. Chang Y.C. Lin Sensor. Actuat. B-Chem. 139 2009 387 393 [22] J. Ling Y.F. Li C.Z. Huang Anal. Chem. 81 2009 1707 1714 [23] E. Katz I. Willner Angew. Chem. Int. Ed. 43 2004 6042 6108 [24] S.E.W. Jones F.W. Campbell R. Baron L. Xiao R.G. Compton J. Phys. Chem. C. 112 2008 17820 17827 [25] O. Bermudez D. Forciniti J. Chromatogr. B 807 2004 17 24 [26] Q. Wu H. Cao Q. Luan J. Zhang Z. Wang J.H. Warner A.A.R. Watt Inorg. Chem. 47 2008 5882 5888 [27] M. Tudorache C. Bala Anal. Bioanal. Chem. 388 2007 565 578 [28] A. Escosura-Muñiz A. Ambrosi A. Merkoçi Trends Anal. Chem. 27 2008 568 584
What problem does this paper attempt to address?
-
Label-free amperometric immunobiosensor based on a gold colloid and Prussian blue nanocomposite film modified carbon ionic liquid electrode
Ke-Jing Huang,De-Jun Niu,Jun-Yong Sun,Xiao-Li Zhu,Jun-Jie Zhu
DOI: https://doi.org/10.1007/s00216-010-3868-4
2010-01-01
Analytical and Bioanalytical Chemistry
Abstract:A novel experimental methodology based on a Prussian blue (PB) and gold nanoparticles (AuNPs) modified carbon ionic liquid electrode (CILE) was developed for use in a label-free amperometric immunosensor for the sensitive detection of human immunoglobulin G (HIgG) as a model protein. The CILE was fabricated by using the ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate as binder. Controllable electrodeposition of PB on the surface of the CILE and coating with 3-aminopropyl triethylene silane (APS) formed a film with high electronic catalytic activity and large surface area for the assembly of AuNPs and further immobilization of HIgG antibody. The electrochemistry of the formed nanocomposite biofilm was investigated by electrochemical techniques including cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. The HIgG concentration was measured through the decrease of amperometric responses in the corresponding specific binding of antigen and antibody. The decreased differential pulse voltammetric values were proportional to the HIgG concentration in two ranges, 0.05–1.25 ng mL −1 and 1.25–40 ng mL −1 , with a detection limit of 0.001 ng mL −1 (S/N = 3). This electrochemical immunoassay combined the specificity of the immunological reaction with the sensitivity of the AuNPs, ionic liquid, and PB amplified electrochemical detection and would therefore be valuable for clinical immunoassays. Figure Cyclic voltammograms of the immunosensor in pH 7.0 phosphate-buffered solution containing 0.1 M KCl at the different scan rate of (from inner to outer) 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, and 800 mVs −1 . The inset shows the linear relationship between the peak currents and the square root of scan rate.
-
Proximity hybridization-regulated electrochemical stripping of silver nanoparticles via nanogold induced deposition for immunoassay.
Jie Li,Jie Wu,Lin Cui,Mengmeng Liu,Feng Yan,Huangxian Ju
DOI: https://doi.org/10.1039/c5an01946j
2016-01-01
Abstract:A simple and disposable electrochemical immunosensor was developed for sensitive and selective detection of a protein biomarker via target-induced proximity hybridization and electrochemical stripping analysis of silver nanoparticles (AgNPs). The immunosensor was prepared by assembling single-stranded DNA modified gold nanoparticles (ssDNA@AuNPs) on a graphene oxide modified disposable screen-printed carbon electrode (SPCE). In the presence of a target protein and two DNA-labeled antibodies, the proximate complex formed in homogeneous solution could hybridize with the assembled DNA to take away AuNPs, which decreased AuNP-catalyzed deposition of AgNPs on the immunosensor surface, and thus the anodic stripping signal. The proposed method avoided the interference of dissolved oxygen. Using the carcinoembryonic antigen (CEA) as a model analyte, this method showed a linear range of four magnitude orders with a detection limit down to 3.9 pg mL(-1). The electrochemical immunosensor possessed preparation convenience, good stability and high sensitivity, and could be extended to sensitive biosensing of other analytes, showing potential application in point-of-care testing.
-
Ultrasensitive multiplexed immunoassay with electrochemical stripping analysis of silver nanoparticles catalytically deposited by gold nanoparticles and enzymatic reaction.
Guosong Lai,Feng Yan,Jie Wu,Chuan Leng,Huangxian Ju
DOI: https://doi.org/10.1021/ac103283p
IF: 7.4
2011-01-01
Analytical Chemistry
Abstract:A novel ultrasensitive multiplexed immunoassay method was developed by combining alkaline phosphatase (ALP)-labeled antibody functionalized gold nanoparticles (ALP-Ab/Au NPs) and enzyme-Au NP catalyzed deposition of silver nanoparticles at a disposable immunosensor array. The immunosensor array was prepared by covalently immobilizing capture antibodies on chitosan modified screen-printed carbon electrodes. After sandwich-type immunoreactions, the ALP-Ab/Au NPs were captured on an immunosensor surface to catalyze the hydrolysis of 3-indoxyl phosphate, which produced an indoxyl intermediate to reduce Ag+. The silver deposition process was catalyzed by both ALP and Au NPs, which amplified the detection signal. The deposited silver was then measured by anodic stripping analysis in KCl solution. Using human and mouse IgG as model analytes, this multiplexed immunoassay method showed wide linear ranges over 4 orders of magnitude with the detection limits down to 4.8 and 6.1 pg/mL, respectively. Acceptable assay results for practical samples could be obtained. The newly designed strategy avoided cross talk and the need of deoxygenation for the electrochemical immunoassay and, thus, provided a promising potential in clinical applications.
-
In Situ Microliter-Droplet Anodic Stripping Voltammetry of Copper Stained on the Gold Label after Galvanic Replacement Reaction Enlargement for Ultrasensitive Immunoassay of Proteins
Xiaoli Qin,Ling Liu,Aigui Xu,Linchun Wang,Yueming Tan,Chao Chen,Qingji Xie
DOI: https://doi.org/10.1016/j.bios.2016.01.024
2016-01-01
The Journal of Physical Chemistry C
Abstract:We report a new protocol for ultrasensitive electrochemical sandwich-type immunosensing, on the basis of signal amplification by gold-label/copper-staining, galvanic replacement reactions (GRRs), and in situ microliter-droplet anodic stripping voltammetry (ASV) after an enhanced cathodic preconcentration of copper. First, a sandwich-type immuno-structure is appropriately assembled at a glassy carbon electrode. Second, copper is selectively stained on the catalytic surfaces of second antibody-conjugated Au nanoparticles through CuSO4-ascorbic acid redox reaction, and the GRRs between HAuCl4 and the stained copper are used to amplify the quantity of copper. Finally, the corresponding antigen is determined based on simultaneous chemical-dissolution/cathodic-preconcentration of copper for in-situ ASV analysis directly at the immunoelectrode. Cyclic voltammetry, electrochemical impedance spectroscopy, quartz crystal microbalance and scanning electron microscopy are used for film characterization and/or process monitoring. Under optimized conditions, ultrasensitive analyses of human immunoglobulin G (IgG) and human carbohydrate antigen 125 (CA125) are achieved. The limits of detection are 0.3 fg mL(-1) (equivalent to 7 IgG molecules in the 6 μL sample employed) for IgG (S/N=3) and 1.3 nU mL(-1) for CA125 (S/N=3), respectively, which are amongst the best reported to date for the two proteins. The theoretical feasibility of such a single-molecule-level amperometric immunoassay is also discussed based on the immunological reaction thermodynamics.
-
Disposable electrochemical immunosensor by using carbon sphere/gold nanoparticle composites as labels for signal amplification.
Qiunan Xu,Feng Yan,Jianping Lei,Chuan Leng,Huangxian Ju
DOI: https://doi.org/10.1002/chem.201200171
2012-01-01
Chemistry - A European Journal
Abstract:This work designed a simple, sensitive, and low-cost immunosensor for the detection of protein marker by using a carbon sphere/gold nanoparticle (CNS/AuNP) composite as an electrochemical label. The nanoscale carbon spheres, prepared with a hydrothermal method by using glucose as raw material, were used to load AuNPs for labeling antibody by electrostatic interaction, which provided a feasible pathway for electron transfer due to the remarkable conductivity. The disposable immunosensor was constructed by coating a polyethylene glycol (PEG) film on a screen-printed carbon-working electrode and then immobilizing capture antibody on the film. With a sandwich-type immunoassay format, the analyte and then the CNS/AuNP-labeled antibody were successively bound to the immunosensor. The bound AuNPs were finally electro-oxidized in 0.1?M HCl to produce AuCl4- for differential pulse voltammetric (DPV) detection. The high-loading capability of AuNPs on CNS for the sandwich-type immunorecognition led to obvious signal amplification. By using human immunoglobulin G (IgG) as model target, the DPV signal of AuNPs after electro-oxidized at optimal potential of +1.40 V for 40 s showed a wide linear dependence on the logarithm of target concentration ranging from 10 pg?mL-1 to 10 ng?mL-1. The detection limit was around 9 pg?mL-1. The immunosensor showed excellent analytical performance with cost effectivity, good fabrication reproducibility, and acceptable precision and accuracy, providing significant potential application in clinical analysis.
-
Electrochemical Metalloimmunoassay Based on Enlargement of Gold Nanoparticle Label Treated with Ag Enhancement System
MJ Wang,H Yuan,XH Ji,ZY Liu,RK Jia,LY Wang,YM Liu,L Ma,JH Li,YB Bai,TJ Li
2003-01-01
Abstract:A novel sensitive electrochemical immunoassay with colloidal gold as the antibody labeling tag and subsequent signal amplification by silver enhancement is described. Colloidal gold was treated by a light-sensitive silver enhancement system which made silver deposit on the surface of colloidal gold(form Au/Ag core-shell structure), followed by the release of the metallic silver atoms anchored on the antibody by oxidative dissolution of them in an acidic solution and the indirect determination of the dissolved Ag+ ions by anodic stripping voltammetry(ASV) at a carbon fiber microelectrode. The electrochemical signal is directly proportional to the amount of analyte(goat IgG) in the standard or a sample. The method was evaluated by means of a noncompetitive heterogeneous immunoassay of immunoglobulin G(IgG) with a concentration as low as 0.2 ng/ mL. The high performance of the method is related to the sensitive ASV determination of silver(I) at a carbon fiber microelectrode and to the release of a large number of Ag+ ions from each silver shell anchored on the analyte(goat IgG).
-
Aptameric System for the Highly Selective and Ultrasensitive Detection of Protein in Human Serum Based on Non-Stripping Gold Nanoparticles
Yanhua Sun,Sheng Cai,Zhijuan Cao,Choiwan Lau,Jianzhong Lu
DOI: https://doi.org/10.1039/c1an15520b
2011-01-01
Abstract:A novel approach is proposed in this study for the development of an aptameric assay system for protein based on non-stripping gold nanoparticles (NPs)-triggered chemiluminescence (CL) upon target binding. The strategy chiefly depends on the formation of a sandwich-type immunocomplex among the capture antibody immobilized on the polystyrene microwells, target protein and aptamer-functionalized gold NPs. Introduction of target protein into the assay system leads to the attachment of gold NPs onto the surface of the microwells and thus the assembled gold NPs could trigger the reaction between luminol and AgNO(3) with a CL emission. Further signal amplification was achieved by a simple gold metal catalytic deposition onto the gold NPs. Such an amplified CL transduction allowed for the detection of model target IgE down to the 50 fM, which is better than most existing aptameric methods for IgE detection. This new protocol also provided a good capability in discriminating IgE from nontarget proteins such as IgG, IgA, IgM and interferon. The practical application of the proposed gold NPs-based immunoassay was successfully carried out for the determination of IgE in 35 human serum samples. Overall, the proposed assay system exhibits excellent analytical characteristics (e.g., a detection limit on the attomolar scale and a linear dynamic range of 4 orders of magnitude), and it is also straightforward to adapt this strategy to detect a spectrum of other proteins by using different aptamers. This new CL strategy might create a novel technology for developing simple biosensors in the sensitive and selective detection of target protein in a variety of clinical, environmental and biodefense applications.
-
Silver nanoparticles in electrochemical immunosensing and the emergence of silver-gold galvanic exchange detection.
Charuksha T Walgama,Nikhil Raj
DOI: https://doi.org/10.1039/d3cc02561f
IF: 4.9
2023-08-21
Chemical Communications
Abstract:Nanoparticle-based electrochemical immunosensors demonstrate high sensitivity toward biomarker detection due to the large surface area of the nanoparticles and their ability to amplify the signal of the target molecule. Additionally, they have a fast response time, relatively lower cost, and can be easily miniaturized for point-of-care applications. Among noble metals, silver nanoparticles (AgNPs) have been extensively used in electrochemical sensors due to their unique properties, such as catalytic activity and excellent electrical conductivity. This Feature Article describes six approaches for incorporating AgNPs in electrochemical platforms, featuring the most recent developments in the silver-gold galvanic exchange-based detection strategy. With a few exceptions, many of these detection methods use AgNP oxidation into Ag+ ions, followed by electrodeposition of Ag+ ions onto the working electrode as zero-valent Ag metal and a final stripping step using a voltammetric technique. Combining these steps provides desirable low detection limits and good sensitivity for various biomarkers. A few other methods involved the reduction of Ag+ ions and depositing them as Ag metal onto the electrode using a reagent mixture so that the striping analysis could be performed. Typically, this reagent mixture includes Ag+ ions, a reducing agent, or an enzyme substrate. Besides, AgNPs have also been directly used to modify the surface of electrodes to facilitate kinetically favored redox-mediated electrochemical reactions. In addition to Ag detection methods, this report will also provide recent examples to illustrate how the size and shape of AgNPs impact the detection limits and sensitivity of an electrochemical assay. Finally, we discuss recent developments in lab-on-a-chip type immunosensors designed explicitly for Ag-based metalloimmunoassay detection, and we envision that this article will provide a comprehensive summary of the operational principles and new insights into such immunoassay systems.
Engineering,Chemistry,Medicine,Materials Science
-
Electrochemical Immunosensor for Casein Based on Gold Nanoparticles and Poly(L-Arginine)/Multi-Walled Carbon Nanotubes Composite Film Functionalized Interface
Qian Cao,Hong Zhao,Yimin Yang,Yujian He,Nan Ding,Jian Wang,Zhijiao Wu,Kaixiang Xiang,Guangwei Wang
DOI: https://doi.org/10.1016/j.bios.2011.01.027
2011-01-01
Abstract:In this paper, a novel electrochemical immunosensor for the determination of casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes (P-L-Arg/MWCNTs) composite film was proposed. The P-L-Arg/MWCNTs composite film was used to modify glassy carbon electrode (GCE) to fabricate P-L-Arg/MWCNTs/GCE through electropolymerization of L-Arginine on MWCNTs/GCE. Gold nanoparticles were adsorbed on the modified electrode to immobilize the casein antibody and to construct the immunosensor. The stepwise assembly process of the immunosensor was characterized by cyclic voltammetry and differential pulse voltammetry. Results demonstrated that the peak currents of [Fe(CN)(6)](3-/4-) redox pair decreased due to the formation of antibody-antigen complex on the modified electrode. The optimization of the adsorption time of gold nanoparticles, the pH of supporting electrolyte and the incubation time were investigated in details. Under optimal conditions, the peak currents obtained by DPV decreased linearly with the increasing casein concentrations in the range from 1 × 10(-7) to 1 × 10(-5) g mL(-1) with a linear coefficiency of 0.993. This electrochemical immunoassay has a low detection limit of 5 × 10(-8) g mL(-1) and was successfully applied to the determination of casein in cheese samples.
-
Nanobody-Based Electrochemical Immunoassay for Ultrasensitive Determination of Apolipoprotein-A1 Using Silver Nanoparticles Loaded Nanohydroxyapatite As Label
Huan Wang,Guanghui Li,Yihe Zhang,Min Zhu,Hongmin Ma,Bin Du,Qin Wei,Yakun Wan
DOI: https://doi.org/10.1021/acs.analchem.5b04063
IF: 7.4
2015-01-01
Analytical Chemistry
Abstract:Nanobodies (Nbs), derived from camelid heavy-chain antibodies, have distinct advantages over conventional antibodies in immunoassay. In this work, Nbs (Nb11 and Nb19) that can bind to different epitopes on apolipoprotein-A1 (Apo-A1) were screened out from an immunized Bactrian camel for the first time. Nb11 was used as capture antibody and fixed on gold nanoparticles (Au NPs) modified screen-printed carbon electrode (SPCE). The silver nanoparticles loaded nanohydroxyapatite (Ag-nHAP) was used as signal tag to label secondary antibody Nb19. A sandwich-type immunological reaction occurred between Apo-A1 and the two Nbs, which brought the Ag-nHAP to the SPCE surface. After the Ag-nHAP were acidically dissolved in the microelectrolytic cell of the SPCE, stripping voltammetric measurement for the released silver ions was performed to obtain an amplified signal. The peak current values increased by the logarithmic values of Apo-A1 concentrations from 10(-4) to 50 ng mL(-1) under optimal conditions. The detection limit was calculated to be 0.02 pg mL(-1). This method was used for the serum samples analysis and achieved satisfactory results. The low cost and high sensitivity make the electrochemical immunosensor suitable for the Apo-A1 detection, which may find promising application in other fields.
-
Fabrication of Electrochemical Immunosensor Using Gold Nanoclusters As Signal Amplification Labels
Liu Hong-Ying,Zhu Jun-Jie
DOI: https://doi.org/10.3724/sp.j.1096.2013.30122
2013-01-01
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY (CHINESE VERSION)
Abstract:A cheap and portable electrochemical immunosensor based on silver. enhanced colloidal gold electrochemical stripping technique and gold nanoclusters (AuNCs) labels was proposed for the detection of human IgG. Inspired by the adhesive proteins that secreted by marine mussels, the stable and robust film. poly (dopamine) was used to immobilize biomolecules (Ab(1)) on an indium tin oxide (ITO) electrode for the fabrication of immunosensor. Then, human IgG and AuNCs-Ab(2) were successively immobilized to the Ab(1) modified ITO electrode. The process for the fabrication of sandwich immunosensor was monitored by electrochemical impedance spectroscopy. Through the immunoreaction between antigen and antibody, IgG could be quantitatively determined by anodic stripping voltammetry. On the basis of the dual signal amplification of AuNCs labels and silver enhancement technique, the sensitivity was improved to 0.5 ng/L. Moreover, the proposed immunosensor could be used in clinical diagnosis.
-
An electrochemical impedimetric arrayed immunosensor based on indium tin oxide electrodes and silver-enhanced gold nanoparticles
Jingjing Zhang,Jinli Wang,Junjie Zhu,Jingjuan Xu,Hongyuan Chen,Danke Xu
DOI: https://doi.org/10.1007/s00604-008-0944-y
2008-01-01
Mikrochimica Acta
Abstract:. A novel sensitive electrochemical impedance immunoassay based on metal nanoparticle labels and ITO electrodes has been developed. First, 2-aminobenzoic acid (2-ABA) was electropolymerized onto an indium tin oxide (ITO) electrode. The coupling reagents 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysulfosuccinimide were then used to activate the electroconductive polymer to form an active ester layer which could react with amino groups of antigen. Subsequently, immunoreaction was carried out between antigen and antibody labeled with gold nanoparticles, followed by the addition of the silver enhancer solution. The charge transfer processes of [Fe(CN) 6 ] 4− /[Fe(CN) 6 ] 3− on the ITO surface were affected due to the formation of silver precipitation on the gold nanoparticles, which was determined by electrochemical impedance spectroscopy. The surface was characterized by scanning electron microscopy. Finally, a multiplexed arrayed immunosensor was is described and the samples of antibody and antibody mixture were assayed specifically. The experimental conditions such as the number of electropolymerization cycles and the time of silver enhancement were examined and optimized. The detection range of antibody labeled with gold nanoparticles was between 10.0 ng mL −1 and 10.0 µg mL −1 .
-
Gold Nanoparticle-Colloidal Carbon Nanosphere Hybrid Material: Preparation, Characterization, and Application for an Amplified Electrochemical Immunoassay
Rongjing Cui,Chang Liu,Jianming Shen,Di Gao,Jun-Jie Zhu,Hong-Yuan Chen
DOI: https://doi.org/10.1002/adfm.200701340
IF: 19
2008-01-01
Advanced Functional Materials
Abstract:A rapid microwave-hydrothermal method has been developed to prepare monodisperse colloidal carbon nanospheres from glucose solution, and gold nanoparticles (AuNPs) are successfully assembled oil the surface of the colloidal carbon nanospheres by a self-assembly approach. The resulting AuNP/colloidal carbon nanosphere hybrid material (AuNP/C) has been characterized and is expected to offer a promising template for biomolecule immobilization and biosensor fabrication because of its satisfactory chemical stability and the good biocompatibility of AuNPs. Herein, as an example, it is demonstrated that the as-prepared AuNP/C hybrid material can be conjugated with horseradish peroxidase-labeled antibody (HRP-Ab(2),) to fabricate HRP-Ab(2)-AuNP/C bioconjugates, which can then be used as a label for the sensitive detection of protein. The amperometric immunosensor fabricated on a carbon nanotube-modified glass carbon electrode was very effective for antibody immobilization. The approach provided a linear response range between 0.01 and 250 ng mL(-1) with a detection limit of 5.6 pg mL(-1). The developed assay method was versatile, offered enhanced performances, and could be easily extended to other protein detection as well as DNA analysis.
-
Aptamer-Au NPs conjugates-accumulated methylene blue for the sensitive electrochemical immunoassay of protein.
Jianlong Wang,Ahsan Munir,Zhonghong Li,H Susan Zhou
DOI: https://doi.org/10.1016/j.talanta.2009.11.035
IF: 6.1
2010-01-01
Talanta
Abstract:In this paper, we combine the advantages of aptamer, nanomaterial and antibody to design an electrochemical sandwich immunoassay for the ultrasensitive detection of human immunoglobulin E (IgE) by using methylene blue (MB) as electrochemical indicator. The sandwich structure is fabricated by using goat anti-human IgE as capturing probe. Aptamer-Au nanoparticles (NPs) conjugates are used both as a sandwich amplification element as well as an accumulation reagent of MB. Once the aptamer-Au NPs conjugates specifically bind to electrode surface, MB molecules are accumulated on its surface by the specific interaction of MB with G base of aptamer-Au NPs conjugates. Therefore, with the increase of human IgE concentration, more aptamer-Au-NPs conjugates are bound, and thus, more MB molecules are accumulated. A good linear relationship is obtained for the detection of human IgE over a range of 1–10,000ng/ml with a lowest detection limit of 0.52ng/ml. In addition, by using BSA, human IgA and human IgM as contrast, the excellent specificity of this sensing system for the detection of human IgE is also demonstrated.
-
Electrochemical Stripping Analysis of Nanogold Label-Induced Silver Deposition for Ultrasensitive Multiplexed Detection of Tumor Markers.
Guosong Lai,Lili Wang,Jie Wu,Huangxian Ju,Feng Yan
DOI: https://doi.org/10.1016/j.aca.2012.01.048
IF: 6.911
2012-01-01
Analytica Chimica Acta
Abstract:A multiplexed electrochemical immunoassay method was developed for simultaneous ultrasensitive measurement of tumor markers based on electrochemical stripping analysis of silver nanoparticles (Ag NPs). The Ag NPs were deposited on a disposable immunosensor array with a reduction reaction catalyzed by nanogold labels. The immunosensor array was prepared by covalently immobilizing capture antibodies on chitosan modified screen-printed carbon electrodes. Through a sandwich-type immunoreaction, antibody-functionalized Au NPs were captured onto immunosensor surface to induce the silver deposition from a silver enhancer solution. The deposited Ag NPs could be directly measured by anodic stripping analysis in KCl solution. The catalytic deposition enhanced the analytical sensitivity for detection of protein markers. The interference of dissolved oxygen could be avoided as the detection was performed with positive stripping potential range. Using carcinoembryonic antigen and α-fetoprotein as model analytes, the proposed multiplexed immunoassay method showed wide linear ranges of three orders of magnitude with the detection limits down to 3.5 and 3.9pgmL−1, respectively. The localized silver deposition, as well as the stripping detection process, eliminated completely the electrochemical cross talk between adjacent immunosensors. The immunosensor array exhibited acceptable reproducibility, stability and accuracy, showing a promising potential in multianalyte determination for clinical application.
-
Dielectrophoresis-Based Protein Enrichment for a Highly Sensitive Immunoassay Using Ag/SiO2 Nanorod Arrays
Zhen Cao,Yu Zhu,Yang Liu,Shurong Dong,Xin Chen,Fan Bai,Shengxin Song,Junxue Fu
DOI: https://doi.org/10.1002/smll.201703265
IF: 13.3
2018-01-01
Small
Abstract:A nanoscale insulator-based dielectrophoresis (iDEP) technique is developed for rapid enrichment of proteins and highly sensitive immunoassays. Dense arrays of nanorods (NDs) by oblique angle deposition create a super high electric field gradient of 2.6 × 1024 V2 m-3 and the concomitant strong dielectrophoresis force successfully traps small proteins at a bias as low as 5 V. 1800-fold enrichment of bovine serum albumin protein at a remarkable rate of up to 180-fold s-1 is achieved using oxide coated Ag nanorod arrays with pre-patterned sawtooth electrodes. Based on this system, an ultrasensitive immunoassay of mouse immunoglobulin G is demonstrated with a reduction in the limit of detection from 5.8 ng mL-1 (37.6 pM) down to 275.3 fg mL-1 (1.8 f M), compared with identical assays performed on glass plates. This methodology is also applied to detect a cancer biomarker prostate-specific antigen spiked in human serum with a detection limit of 2.6 ng mL-1 . This high sensitivity results from rapid biomarker enrichment and metal enhanced fluorescence through the integration of nanostructures. The concentrated proteins also accelerate binding kinetics and enable signal saturation within 1 min. Given the easy fabrication process, this nanoscale iDEP system provides a highly sensitive detection platform for point-of-care diagnostics.
-
Development of the multi-functionalized gold nanoparticles with electrochemical-based immunoassay for protein A detection
Chi-Chang Lin,Li-Chia Chen,Chien-Hao Huang,Shinn-Jyh Ding,Chia-Chin Chang,Hsien-Chang Chang
DOI: https://doi.org/10.1016/j.jelechem.2008.03.014
IF: 4.598
2008-01-01
Journal of Electroanalytical Chemistry
Abstract:This paper reports an amplification procedure application of multi-functionalized gold nanoparticles (MFAuNPs) which was used for electrochemical impedance immunosensor. The modified electrode which was utilized for the affinity adsorption of protein A, was fabricated by stepwise immobilization of 1, 6-hexanedithiol, AuNPs, and IgG on the gold electrode via self-assembling technique. The interfacial properties of the modified electrodes were evaluated in the presence of Fe(CN)64-/3- couple redox as a probe by cyclic voltammetry and electrochemical impedance spectroscopy. An equivalent circuit model with a constant phase element was used to interpret the obtained impedance spectra. The electrochemical behavior of the redox probe was affected by the accumulation of treated substances on the electrode surface. There is no significant increase in the electron transfer resistance after the binding of protein A to IgG on the electrode surface without amplification. The changes in the electron transfer resistance on the IgG-modified electrodes became more sensitive after the MFAuNPs were introduced for signal amplification. The increments of amplified impedance showed good correlation of the detection of protein A in the range of 5–1000pg/mL with a detection limit of 1pg/mL. The development of a rapid, facile, and sensitive amplification method capable to detect biomolecules in the picogram range, utilizing EIS measurement, may be achieved in this study.
-
Electrochemical Glycoprotein Aptasensors Based on the In-Situ Aggregation of Silver Nanoparticles Induced by 4-Mercaptophenylboronic Acid
Ning Xia,Cheng,Lin Liu,Peizhen Peng,Chaoyang Liu,Junxue Chen
DOI: https://doi.org/10.1007/s00604-017-2488-5
IF: 5.7
2017-01-01
Microchimica Acta
Abstract:The authors report on an amperometric method for the determination of glycoprotein by using an aptamer as the bioreceptor. The detection scheme is making use of aggregated citrate-capped silver nanoparticles (AgNPs) on a gold electrode. Aggregation is accomplished by addition of 4-mercaptophenylboronic acid (MPBA) which acts as a cross-linker due to the formation of Ag-S bonds and of boronate esters. A thiolated DNA aptamer was then attached to the electrode in order to capture glycoprotein. Once captured, the glycoprotein reacts with MPBA through the formation of boronate esters. The electrochemical signal is thus amplified by the formation of a network of AgNPs which act as redox reporters. To demonstrate the feasibility of the method, prostate specific antigen (PSA) was chosen as a model analyte. The detection limit for PSA is as low as 0.2 pg mL−1. In our preception, this method provides a powerful tool for studying the glycan function in biological and physiological processes.
-
Fluorescence enhancement of silver nanoparticle hybrid probes and ultrasensitive detection of IgE.
Hui Li,Weibing Qiang,Maika Vuki,Danke Xu,Hong-Yuan Chen
DOI: https://doi.org/10.1021/ac201574s
IF: 7.4
2011-01-01
Analytical Chemistry
Abstract:An ultrasensitive protein assay method was developed based on silver nanoparticle (AgNP) hybrid probes and metal-enhanced fluorescence. Two aptamer based silver nanoparticles, Aptamer/Oligomer-A/Cy3-modified AgNPs (Tag-A) and Aptamer/Oligomer-B/Cy3-modified AgNPs (Tag-B) were hybridized to form a silver nanoparticle aggregate that produced a red shift and broadening of the Localized Surface Plasmon Resonance (LSPR) peak. The enhanced fluorescence resulted from the increased content of Cy3 molecules and their emission resonance coupled to the broadened localized surface plasmon (LSP) of AgNP aggregate. The separation distance between Cy3 and AgNPs was 8 nm which was the most optimal for metal enhanced fluorescence and the separation distance between adjacent AgNPs was about 16 nm and this was controlled by the lengths of oligomer-A and oligomer-B. The protein array was prepared by covalently immobilizing capture antibodies on aldehyde-coated slide. After addition of protein IgE sample, two kinds of aptamer-modified AgNPs (Tag-A and Tag-B) were employed to specifically recognize IgE and form the AgNP aggregate on the arrays based on their hybridization. The detection property of the aptamer-modified AgNP aggregate was compared to two other modified aptamer-based probes, aptamer-modified Cy3 and Tag-A. The modified AgNP hybrid probe (Tag-A and Tag-B) showed remarkable superiority in both sensitivity and detection limit due to the formed AgNP aggregate. The new hybrid probe also produced a wider linear range from 0.49 to 1000 ng/mL. with the detection limit reduced to 40 pg/mL (211 fM). The presented method showed that the newly designed strategy of combining aptamer-based nanomaterials to form aggregates results in a highly sensitive optical detection method based on localized surface plasmon.
-
Triple Signal Amplification of Graphene Film, Polybead Carried Gold Nanoparticles As Tracing Tag and Silver Deposition for Ultrasensitive Electrochemical Immunosensing.
Dajie Lin,Jie Wu,Min Wang,Feng Yan,Huangxian Ju
DOI: https://doi.org/10.1021/ac3001435
IF: 7.4
2012-01-01
Analytical Chemistry
Abstract:A triple signal amplification strategy was designed for ultrasensitive immunosensing of cancer biomarker. This strategy was achieved using graphene to modify immunosensor surface for accelerating electron transfer, poly(styrene-co-acrylic acid) microbead (PSA) carried gold nanoparticles (AuNPs) as tracing tag to label signal antibody (Ab(2)) and AuNPs induced silver deposition for anodic stripping analysis. The immunosensor was constructed by covalently immobilizing capture antibody on chitosan/electrochemically reduced graphene oxide film modified glass carbon electrode. The in situ synthesis of AuNPs led to the loading of numerous AuNPs on PSA surface and convenient labeling of the tag to Ab(2). With a sandwich-type immunoreaction, the AuNPs/PSA labeled Ab(2) was captured on the surface of an immunosensor to further induce a silver deposition process. The electrochemical stripping signal of the deposited silver nanoparticles in KCl was used to monitor the immunoreaction. The triple signal amplification greatly enhanced the sensitivity for biomarker detection. The proposed method could detect carcinoembryonic antigen with a linear range of 0.5 pg mL(-1) to 0.5 ng mL(-1) and a detection limit down to 0.12 pg mL(-1). The immunosensor exhibited good stability and acceptable reproducibility and accuracy, indicating potential applications in clinical diagnostics.