Stereo-staged Process of Low NOx Combustion Technique in Hengyun Power Plant 2 × 210 MW Boiler Applications

FEI Jun,WU Bi-ke,LI Yun-feng,GUO Zhi-ming,JIA Feng-yang,SUN Rui,SUN Shao-zeng
DOI: https://doi.org/10.3969/j.issn.1671-1815.2010.34.016
2010-01-01
Abstract:2×210 MW boilers were retrofitted by low-NOx burners and over-fired air technology to realize that fuel was staged in horizontal direction and air was staged in vertical direction.Experiments were carried out under the different ways of secondary air and the different share of OFA.According to analysis of results shows that,NOx emissions in flue gas was 550 mg/m3 before retrofitted,and under different air distribution modes of secondary air,NOx emissions in flue gas was down to 230 mg/m3,decreased by about 58%(converted to O2 = 6%)after retrofitted.NOx emissions were related to the reducing atmosphere around the burner nozzles.The air around the nozzles influences the conversion of fuel nitrogen.Meanwhile,there is a reasonable share of OFA,can promote the lowest NOx emission levels of concentration.
What problem does this paper attempt to address?