Optimization of HPLC measurement of residual Pymetrozine in broccoli

Hu Xuan,Shen Guoqing,Lu Yitong,Zhang Yan
DOI: https://doi.org/10.3969/j.issn.1001-3865.2008.09.010
2008-01-01
Abstract:An efficient method for analysis of residual Pymetrozine was developed.Aetonitrile and methylene chloride were first employed to extract Pymetrozine from the broccoli,followed by purification with ethyl acetate,and then HPLC to quantify.An orthogonal experimental program of experimental runs were conducted to produce the best combination of four important factors;temperature=20 ℃,acetonitrile/water=85/15,sample size=10 μL,fluid flow=1 mL/min.The minimum detectable quantity(LOQ) was 1.0×10-10 g,while the limit of detection(LOD) was 0.005 mg/kg.The relative standard deviation(RSD) was 0.78%-3.14%,and the overall recovery was between 87.29%-93.60%.The measurements of this method have the precision required for detection of pesticide residues.
What problem does this paper attempt to address?