Abstract:Objective:To develop LC/electrospray ionization (ESI)-MS method for the simultaneous determina- tion of isoniazid,acetylhydrazine and hydrazine in mice plasma.Methods:The analytes were treated by methanol precipitation to remove protein component from mice plasma,then reacted with a reagent 3 -methoxybenzadlehyde (MBA) to form derivatization.The derivatized products were separated on an Agilent Zorbax XDB-Cs column.The mobile phase consisted of methanol -5 mmol·L~(-1) ammonium acetate buffer ( pH 5.0) solution (60:40) at a flow rate of 0.5 mL·min~(-1).A mass spectrometer equipped with electrospray ionization source was adopted as detector and operated in positive ion mode.In selected ion monitoring (SIM) mode,the ion combinations of m/z 256.1,m/ z 193.2 and m/z 151.1 were used to quantify the derivatives of isoniazid,acetylhydrazine and hydrazine,respective- ly.Results:The linear concentration ranges of the calibration curves for isoniazid,acetylhydrazine and hydrazine were 1 -64 μg·mL~(-1),0.05-3.2 μg·mL~(-1) and 0.025-1.6 μg·mL~(-1),respectively,and the limit of quantifi- cation were 1 μg·mL~(-1),0.05 μg·mL~(-1) and 0.025 μg·mL~(-1),respectively.The average recovery of isoniazid, aeetylhydrazine and hydrazine were 98.9%,98.0% and 97.2%,RSD were 2.7%,2.4%,3.1%,respectively. Conclusion:The method is proved to be suitable for the simultaneous determination of isoniazid,acetylhydrazine and hydrazine in mice plasma and its pharmacokinetic study.