On the Association Between Building Ventilation Characteristics, Some Indoor Environmental Exposures, Some Allergic Manifestations and Subjective Symptom Reports

J SUNDELL
DOI: https://doi.org/10.1111/j.1600-0668.1994.tb00031.x
IF: 6.5539
1994-01-01
Indoor Air
Abstract:The prevalence of some allergic and other hypersensitivity disorders has increased during recent decades, especially in industrialized countries. In Sweden, allergy towards house dust mites has increased and is linked to the home environment. In many countries, subjectively reported indoor-related symptoms such as those contained in the sick-building syndrome (SBS) have become a problem of concern. Typically, SBS involves general symptoms (e.g. headache and fatigue), mucous membrane symptoms (e.g. irritation of upper airways and the eye) and skin symptoms. SBS is attributed to a specific indoor environment, typically the place of work or the home. Great changes in building hygiene have taken place within recent decades due to e.g. the use of many new building materials, new technologies and energy-saving measures that have reduced ventilation.The aims of the present thesis are 1) to assess the associations between ventilation characteristics of homes, house dust mite infestation and allergy among children; 2) to assess the association between ventilation characteristics and occurrence of reported SBS-related symptoms among office workers; 3) to analyze associations between reported SBS-related symptoms and the reported sensation of dryness and associations between the reported sensation of dryness and physical air humidity, room characteristics and chemical factors; and 4) to study changes in total volatile organic compounds (TVOC) or formaldehyde concentration from outdoor air to room air and to study the associations between SBS-related symptom reports and concentrations of TVOC and formaldehyde in room air.The results from 3 different building and occupant studies are included. The first was a study in 2 steps on the association between allergic diseases among children (n = 160). house dust mite infestation, indoor exposure to air humidity, VOC and formaldehyde and the characteristics of the ventilation of homes (step 1: case-control study; step 2: comparative study of homes with high or low house dust mite infestation). The second was an office illness study in 3 steps on associations between building, room and ventilation characteristics, TVOC and formaldehyde and occurrence of reported SBS-related symptoms among office workers (n = 5986) (step 1: screening questionnaire; step 2: case-control studies; step 3: comparative study of buildings in which occupants exhibit a high or low prevalence of symptoms). The third study was a technical and chemical field study on the possible re-entrainment of indoor air pollutants (formaldehyde) via rotary heat exchangers.The methods used in the three studies comprised questionnaires, clinical investigations, site inspections and environmental measurements.In a region with cold winters, house dust mite infestation and thus house dust mite allergy was found to be associated with a low total outdoor air flow rate of the home and of the bedroom as well. A low outdoor air flow rate in offices was associated with an elevated prevalence of SBS symptoms. Ventilation operating hours less than 10 h per day, the presence of photocopiers, video display terminal work, a low rating of psychosocial conditions at work, female sex and reported asthma, eczema and skin sensitivity to sunlight were associated with an elevated risk of SBS symptoms. The type of ventilation system, recirculation of air and presence of rotary heat exchangers were not demonstrated to be associated with an elevated risk of SBS symptoms. TVOC may not be a valid construct of indoor air pollution from a health perspective in the low concentration exposure range. Indoor air chemistry, involving, for example, the possible transformation products of VOC may be important. The perception of ''dry air'' was associated with SBS symptoms. This perception was not demonstrated to be associated with physical air humidity.
What problem does this paper attempt to address?