Prevention of Stress Fracture through Application of Electric Stimulation Combined with Ultrasound in Rabbits

Zeng Guigang,Zhao Xianzhe,Cai Liang,Li Jun,Peng Haidong,Zhang Shen,Qiao Weiwei,Shi Hongcheng
DOI: https://doi.org/10.3969/j.issn.1000-6710.2012.11.006
2012-01-01
Abstract:Objective To observe the effects of low frequency electric stimulation(LFES) combined with low intensity pulsed ultrasound(LIPUS) on the prevention of stress fracture in rabbits.Methods 12 rabbits were randomly divided into 3 groups:5 in model group,5 in treatment group and 2 in blank group.Animals in the model group and treatment group were forced to run or jump in a special device under the electrical stimulation 300 times per day,6 days per week for a total of 5 weeks.LFES and LIPUS were applied to the treatment group after training,whereas the model group received no any treatment after training.Radiocounting ratio,BMD,maximum load,max-stress and elastic modulus,and pathological changes were determined after 5 weeks through single photon emission computerized tomography and histological technique,respectively.Results The radiocounting ratio of tibia in the model group were higher than that in treatment group and blank group(P<0.05),there was no difference in radiocounting ratio of tibia between treatment group and blank group(P>0.05).There was no difference in BMD in three groups(P>0.05).The maximum load,max-stress and elastic modulus in the model group were lower than other groups(P<0.05).The tibia injury in the model group was more serious than treatment group and blank group.Conclusion LFES combined with LIPUS can effectively prevent stress fracture of tibia in rabbits.
What problem does this paper attempt to address?