Biomechanical study on a new expanded cage for lumbar interbody fusion

ZHANG Hua,YE Xiaojian,XU Guohua,HE Hailong,LI Jiashun
DOI: https://doi.org/10.3969/j.issn.1672-2957.2009.04.007
2009-01-01
Journal of Spinal Surgery
Abstract:Objective To evaluate the biomechanical stability of lumbar functional segment unit after insertion with a newly designed expanded cage without addition of pedicle screws.Methods Fifteen human cadavers' lumbar spine specimens were divided into 3 groups: cylindrical thread cage group(Interfix group),box-shaped cage group(Telamon group),and expanded cage group(Expanded group).The single cage was implanted into intervertebral disc without addition of pedicle screws by the method of posterior lumbar interbody fusion(PLIF).The range of motion(ROM) of all the groups were recorded by 3-dimensional 6-directional movement using a mechanical testing machine.The cadaver lumbar segments were also used to evaluate the max anti-pullout strength.Results The ROM of Expanded group was lower than that of Interfix and Telamon groups(P<0.05).Expanded cage required a median pullout force of 747 N,which was 98.1% higher than that of Interfix group and 32.4% higher than that of Telamon group.Conclusion According to the biomechanics in vitro,the expanded cage has higher biomechanical initial stability than cylindrical thread cage and box-shaped cage,and also larger anti-slide capability,so theoretically it can be used alone under strict indication.