High-frequency ultrasounic performance and analyses of 92 cases children's mesenteric lymphadenitis

ZHANG Xiao-rong,CHEN Fei,XING Shu-ling
DOI: https://doi.org/10.3969/j.issn.1001-0025.2011.04.006
2011-01-01
Abstract:Objective:To compare and analysis ultrasonic performance of lymph nodes between children suffered from mesenteric lymphadenitis and normal children.Methods:Using color Doppler ultrasound for a comparative examination on 92 abdominal lymph node cases of children with mesenteric lymphadenitis and 50 healthy cases.The examination included measuring four large abdominal lymph nodes,and making statistic analyses of the diagnosed results;observing the size of the measured celiac lymph nodes,the diameter ratio,site,number,the cortex and the characteristics of lymph node door echo,the hilus position and the possibility of the fusion.Results:With the growth of their age,normal children's abdominal lymph nodes reduce,whereas the abdominal lymph node of abnormal children aged 0-5 and 5-10 were all increased and strikingly different.With the diagnostic standard two or more celiac lymph nodes whose biggest transverse diameter was over 0.4cm,the sensibility was 100% in the group of aged 0-5,and its specificity was 84%.In the group of aged 5-10,both the sensitivity and specificity were 100%.Conclusion:Checking and analysis of high-frequency ultrasound in children can help us to know normal performance of lymph node and mesenteric lymphadenitis.
What problem does this paper attempt to address?