Clinical value of dual-energy X-ray absorptiometry in the measurement of bilateral femoral bone mineral density in 1055 cases

Gong J,Wu QL,Xu H
DOI: https://doi.org/10.3321/j.issn:1673-8225.2007.02.051
2007-01-01
Abstract:AIM:To investigate the difference in bone mineral density(BMD)at the proximal end of bilateral femora,and explore the diagnostic value of dual-energy X-ray absorptiometry(DXA)densitometry in measuring the bilateral femoral BMD.METHODS:1 055 subjects(including 789 females and 266 females)in Guangzhou district,who were measured of the BMD between November 2001 and December 2005 in First Hospital Affiliated to Jinan University were selected.①All patients were measured of the BMD with DXA in dual femora(femoral neck,femoral trochanter,upper femoral neck and total hip joint).The BMD in the proximal end were compared between bilateral femora.② 500 postmenopausal females were diagnosed based on the lowest T-score of bilateral measurement sites according to the diagnostic classification established by the World Health Organization.The differences in measurement of BMD in bilateral proximal ends were compared from the diagnostic level.③ Thirty enrolled subjects(including 8 males and 22 females with the age ranged 21-72 years and the average age of 42.1 years)were measured of the BMD twice,and the changes precision as well as the least significant change(LSC)in each measurement site were calculated.RESULTS:① There was high positive correlation(r = 0.88-0.97,P < 0.001)between the left and right femoral BMD values in both female group and male group,while there were no significant differences between bilateral femoral BMD values of each part in male group.There were small(mean BMD 0.030 g/cm2)differences in BMD value of total hip in the female group,and there was statistical significance in the differences(BMD difference = 0.030 g/cm2,t =2.387,P =0.017),which was higher in the right femur than that in the left.② In 500 postmenopause women,83.2%(416/500)of them were with the same in the diagnosis between left and right femurs,and 84 patients(16.8%)were different in the diagnosis between left and right femurs.After precision correction,there was a diagnosis discordance in 7.0 %(35/500)of patients.③ The precision in unilateral measurement at different parts of femoral proximal ends ranged from 0.7% to 2.2%,while the precision in bilateral measurements at corresponding parts ranged from 0.6% to 1.2%.The precision in bilateral measurement was 20%-45% higher than the precision in unilateral measurement.CONCLUSION:① There are significant but small differences between the right and left proximal femur BMD values in women of Guangzhou district.② The precision in dual femur measurements is higher than that in unilateral femur measurement,which contributes to detection of changes in BMD.③ Partial dual measurement in individuals can change the diagnostic result of unilateral measurement,and there is possibility of missed diagnosis in unilateral measurement.
What problem does this paper attempt to address?