Automatic Verification of Plan Data Transfer for Online Adaptive Radiotherapy

G. Chen,E. Ahunbay,A. Li
DOI: https://doi.org/10.1016/j.ijrobp.2010.07.1710
2010-01-01
Abstract:Verification of the plan data transferred from planning system to delivery machine prior to treatment delivery is a necessary step for quality assurance (QA) and safety and is often performed via visual inspection. However, such visual inspection can be time consuming for intensity modulated radiotherapy (IMRT), a particular concern for online adaptive re-planning, and human errors are inevitable. The purpose of this work is to develop a software tool to automatically verify the plan data transfer for online adaptive radiotherapy. A software tool was developed using Microsoft Visual C++. The tool can read/extract treatment plan data including gantry/collimator/couch parameters, MLC positions, and monitor unit (MU) numbers from three sources: (1) a treatment planning system (TPS) (RealART, Prowess, or Xio, CMS) via RTP link, DICOM transfer or a direct interface to TPS, (2) an independent MU calculation system (RadCalc, LifeLine Software Inc.) for secondary MU check, and (3) a record and verify (R&V) system (Lantis, Siemens, or Mosaiq, Elekta) by retrieving the imported and stored plan data with an open database connectivity (ODBC) connection. The ODBC connection to the R&V system database was created to be read only and password protected. The data from aforementioned three sources were compared to verify the consistency between the data in the TPS and those stored in the R&V system and to search for any discrepancy between the MU numbers calculated by the TPS and by the secondary MU check program. The comparison results were output by the software tool. The verification software tool was tested with real IMRT plans from regular treatments and from the online adaptive radiotherapy. The tool was capable of automatically detecting any inconsistency between the beam data from the TPS and the data transferred and stored in the R&V system and identifying any discrepancy between the MU numbers calculated from the TPS and from the secondary MU check program. The execution of the tool lasted only a few seconds. The tool is being integrated into our clinical online adaptive re-planning process as a necessary QA step to be performed prior to the delivery of the adaptive plan. The use of this tool speeded the online adaptive process by eliminating the manual and tedious visual inspection. The tool was also found to be useful for regular plan check and verification. A QA software tool has been developed to automatically verify the plan data transfer from the planning system to the R&V system and to identify discrepancy in MU calculations between the planning system and the secondary MU check. This tool speeds up the online adaptive re-planning process and improves QA and safety.
What problem does this paper attempt to address?