A Study of PVDF Langmuir‐Blodgett Thin Film Using Quartz Crystal Microbalance

Zhihua Ying,Yadong Jiang,Xiaosong Du,Guangzhong Xie,Yajie Yang
DOI: https://doi.org/10.1002/app.26731
IF: 3
2007-01-01
Journal of Applied Polymer Science
Abstract:Poly(vinylidene fluoride) (PVDF) was deposited onto a quartz crystal microbalance (QCM), using a standard Langmuir-Blodgett (LB) thin film deposition procedure. QCM technique was used to monitor the reproducibility of the LB film monolayer, and the fabricated QCM sensor was employed to detect the dimethyl methyl phosphonate (DMMP) vapor, a simulant of nerve agents. The results show that PVDF was successfully deposited from the water surface onto the quartz crystal substrate. The PVDF LB film is found to be highly sensitive to DMMP vapor, and frequency shifts are linear to the concentrations. The response of the sensor against DMMP is fast, large, and reversible. (C) 2007 Wiley Periodicals, Inc.
What problem does this paper attempt to address?