Influence on Dose Distribution by Beam Direction and Beam Number in Inverse Intensity-Modulated for Nasopharyngeal Carcinoma

CHANG Xi,XU Zhi-yong,ZHOU Li-jun,WANG Xiao-shen,ZHU Ji,HU Chao-su,FU Xiao-long
DOI: https://doi.org/10.3969/j.issn.1007-3639.2007.04.013
2007-01-01
Abstract:Background and purpose:Intensity-modulated radiation therapy (IMRT) is now widely used in the treatment of nasophyngeal carcinoma(NPC). How to optimize treatment planning is the most challenging problem in the clinic in terms of dosimetry due to the complicated anatomy. Dose distribution will be influenced by many physical parameters including beam number and beam direction and the optimization process could be very time-consuming. This study was to evaluate the influence of different beam number and beam angle on dose distribution in the treatment of NPC by IMRT and hopefully to set up the basic points on how to plan IMRT with shorter time than before. Methods:20 NPC patients with early stage(10) and locally advanced stage(10) were selected . IMRT treatment plan with seven beams and nine beams were formulated for every patient. Two beam angulus incidentiae (A, B groups) for seven beams plan were designed. The same physical objective function was applied for the same patient and both groups . We compared seven beams plan with different beam angulus incidentiae to optimize beam angle, and then seven beams plan with the preferable angle is compared with nine beam plan to optimize beam number. Plans were evaluated in terms of target coverage, target dose uniformity, target conformability, monitor unit and segment numbers.Results:In the patients with early stage NPC all parameters were met in both seven beams plans and nine beams plans,but MUs and segment number were fewer in group A than those in group B. In the patients with locally advanced stage NPC, although MUs and segment number were fewer in group A and group B than those in nine beams plans, target dose coverage and target dose uniformity in nine beams plans were superior to those in seven beams plans.Conclusions:The beam angle and the number of beams have influence upon dose distribution, the dose distribution would be improved for large volume target with the increment of beam number. Taking therapeutic index (TCP/NTCP) into account we suggest that the seven beams plan can give a successful solution for early stage NPC and nine beams plan are recommended for locally advanced stage NPC.
What problem does this paper attempt to address?