Quasi-static test of slab-column connections and calculating method of punching shear strength outside stud group

Zhang Yang,Dai Weiming,Qian Jiaru,Tao Xuekang
DOI: https://doi.org/10.19701/j.jzjg.2013.12.009
2013-01-01
Abstract:The quasi-static test of two slab-column connections,which punching shear failure of slab occurred outside the stud group,were introduced.An outline of punching shear-critical section outside the stud group was proposed.Based on the test results and related references,a formula,which took into consideration of punching-shear span factor and had the same form with the punching shear strength formula of concrete slab specified in Code for design of concrete structures(GB 50010—2010),was recommended to calculate punching shear strength outside the stud group of slab.The punching shear strength obtained by using the formula is well consistent with that obtained by the test.
What problem does this paper attempt to address?