Quantitative Assessment of Radiation Therapy Associated Breast Tissue Toxicity

T. Liu,J. Zhou,S. A. Woodhouse,P. B. Schift,P. Zhang,K. S. Osterman,S. Islam,Z. F. Lu,E. Pile-Spellman,G. J. Kutcher
DOI: https://doi.org/10.1016/j.ijrobp.2007.07.1225
2007-01-01
Abstract:To investigate the use of ultrasound tissue characterization (UTC) imaging to quantitatively evaluate normal tissue toxicity in breast cancer radiation treatment. For women with early stage breast cancer, breast-conservation surgery in combination with radiation therapy is an effective treatment. However, efficacy of radiation therapy is limited by radiation injury to normal tissue. There is currently no objective means of measuring breast tissue injury/toxicity in the clinic. We investigated the use of UTC to examine skin and subcutaneous tissue of the breast. Twenty two breast cancer patients were enrolled. All patients received a standard course of radiation: the whole breast received 50–50.4 Gy followed by an electron boost of 10–16 Gy at the lumpectomy site. Follow up time was 6 to 94 months with a median of 22 months. Patients were scanned with a clinical Ultrasonix® scanner in a supine position. Radio-frequency echo signals were acquired from the treated and the contra-lateral breast. Our UTC technique analyzes the RF signals and extracts spectral features that are associated with properties of tissue microstructures. Four UTC parameters were computed to quantitatively measure toxicity: skin thickness, UTC slope, intercept and midband fit (MBF). Statistical analysis was performed to correlate the UTC findings with clinical assessments (RTOG clinical toxicity scale). UTC measurements for the treated breast were compared with the contra-lateral (untreated) breast for quantitative assessment of normal tissue radiation toxicity. Two breast images are shown in the Figure: (a) treated right breast and (b) untreated left breast. The skin thickening (arrows) and hyper-echogenecity of the fat were observed. The plot on the right is the UTC 1-D power spectra. For all patients, the average thickness of the treated breast skin is 2.50 ± 0.82 mm while untreated skin is 1.68 ± 0.62 mm. For the underlying tissue, there are significant changes for the treated breast in the UTC intercept (p = 0.017) and midband fit (p = 0.002), except slope (p = 0.077). Changes in midband fit were primarily related to soft tissue stiffness, which correlates the presence of fibrosis. The UTC evaluations were consistent with the clinical breast toxicity assessments. Ultrasound tissue characterization provides an objective quantitative method of assessing radiation damage to the skin and the underlying breast tissue. This tool will become increasingly valuable as we evaluate new strategies for breast cancer radiation therapy.
What problem does this paper attempt to address?