Factorial Design Applied to Flux Decline of Anionic Polyacrylamide Removal from Water by Modified Polyvinylidene Fluoride Ultrafiltration Membranes

X. S. Yi,W. X. Shi,S. L. Yu,X. H. Li,N. Sun,C. He
DOI: https://doi.org/10.1016/j.desal.2010.10.019
IF: 11.211
2011-01-01
Desalination
Abstract:Experiments were performed with a lab-scale setup under constant flux conditions with synthetic feed water containing anionic polyacrylamide (APAM) colloid as a fouling component to predict the decline of UF process. A four-factor two-level full factorial design analysis was conducted to screen the significant factors influencing relative flux reduction (J/J0) of APAM with 6880kDa in ultrafiltration (UF) process. Factors investigated were pH of the solution (3~10), total dissolved solids (TDS) (0~3.5g/L), concentrations of APAM (10~100mg/L), and transmembrane pressures (TMP) (0.07~0.2MPa). A significant TMP effect on J/J0 of this APAM UF process was obtained. Analysis of variance (ANOVA) showed a high coefficient of determination value (R2=0.9658) and satisfactory prediction regression model was derived. The optimum UF TMP, pH and initial concentration of solution were found to be 0.07MPa, 3, and 10mg/L, respectively. Under the optimal value of process parameters, J/J0 (24.9%) was obtained for this UF process after 30 min.