On oxygenation status of three types of mechanical ventilation in laparoscopic gastric banding

Guan Lei,Li Qun
DOI: https://doi.org/10.3969/j.issn.1009-6604.2007.06.024
2007-01-01
Abstract:Objective To investigate effects of three types of mechanical ventilation on oxygenation status in laparoscopic gastric banding for the treatment of morbid obesity.Methods Twenty-four morbidly obese patients scheduled for laparoscopic gastric banding were divided into three groups.The Group A was given a tidal volume of 12 ml/kg and a respiratory rate of 10 times/min,the Group B,a tidal volume of 20 ml/kg and a respiratory rate of 10 times/min,and the Group C,a tidal volume of 12 ml/kg and a respiratory rate of 20 times/min,respectively.The measurement of arterial blood for pH value,PO2,PCO2,Plat Pressure,Peak Pressure,and AaDO2 was conducted before(T1) and after pneumoperitoneum(T2). Results After pneumoperitoneum,the Group B had significantly higher Plat Pressure(33.2±1.8 cm H2O) and Peak Pressure(36.3±1.6 cm H2O) than the Group A(Plat Pressure: 29.5±3.9 cm H2O,q=3.053,P<0.05;Peak Pressure: 33.0±2.9 cm H2O,q=2.823,P<0.05) and the Group C(Plat Pressure: 28.0±4.1 cm H2O,q=4.290,P<0.05;Peak Pressure: 31.8±2.8 cm H2O,q=4.704,P<0.05).There were no significant differences among the three groups in other parameters. Conclusions During laparoscopic gastric banding for morbid obesity,the oxygenation status cannot be promoted by increasing the tidal volume up to 20 ml/kg or the respiratory rate up to 20 times/min.
What problem does this paper attempt to address?