A High Efficiency Step-down PFC with Constant on Time Control

YANG Jian-you,WU Xin-ke,ZHANG Jun-ming,QIAN Zhao-ming
DOI: https://doi.org/10.3969/j.issn.1000-100x.2010.11.012
IF: 5.967
2010-01-01
IEEE Transactions on Power Electronics
Abstract:In universal voltage input application,the Buck PFC can achieve high efficiency in the entire universal input voltage range compared to Boost PFC.A critical mode(CRM)ZVS Buck converter with constant on-time control is proposed.This paper analyses the operation principle of the circuit and the design methodology and criteria for high efficiency and low harmonics of the CRM Buck AC/DC converter are presented.A 100 W prototype designed according to the proposed design criteria shows that the input current harmonics meet the IEC61000-3-2(Class D)standard and the efficiency is higher than 96.5% during the universal input range.
What problem does this paper attempt to address?