Analysis on Integrated Energy Efficiency for Vertical Sun-shading Blind of a Typical Office Building in Guangzhou

Ji WU,Qing-lin MENG,Lei ZHANG,Yu-feng ZHANG
DOI: https://doi.org/10.3969/j.issn.1002-8528.2009.02.019
2009-01-01
Building Science
Abstract:In hot summer and warm winter area,decreasing the shading coefficient of the glazing system is one of the most effective methods to reduce the cooling energy consumption.However,it will lead to the less use of the daylight,and the electric lighting energy consumption will be increased.Therefore,a balance adjustment between the energy consumptions of cooling and electric lighting should be carried out.In this paper,energy consumptions of cooling and electric lighting were simulated by taking the total energy consumption as the control index.Furthermore,optimization design for the structure of vertical sun-shading blinds,including extend length,number and slip angle,was preformed.The results indicated that the increase of the extend length or the number of blinds would lead to the decrease of the cooling energy consumption,while the electric lighting energy consumption would be increased,and the total one would be reduced as an overall effect.On the other hand,when the slip angle was changed,the total energy consumption would be firstly increased and then decreased.When the slip angle was minus 15°,the total energy consumption had the peak value.