Monitoring the Perioperative Coagulation Function of Children with Congenital Heart Disease

HUANG Yan-hui,CHEN Yue,ZHU De-ming,ZHANG Jian-wei,XU Mei-ying
DOI: https://doi.org/10.3969/j.issn.1672-1403.2007.01.002
2007-01-01
Abstract:OBJECTIVE Using Sonoclot coagulation and platelet function analyzer system to monitor the coagulation function of children with acyanotic or cyanotic congenital heart disease and evaluate this method.METHODS 60 children with congenital heart disease were collected randomly and divided into acyanotic group(N group,n=30)and cyanotic group(C group,n=30).Central venous blood was withdrawed to measure SonACT,Clot Rate and PF at the following time points: after anesthesia(T1),10 minutes after protamine administration(T2),and 24 hour mediastinal chest tube drainage was recorded.RESULTS The SonACT,Clot Rate and PF of N and C groups both changed at T2 compared with those at T1.The Clot Rate of N group has significantly statistic difference at T1,T2 compared with that of C group.24 hour mediastinal chest tube drainage has significantly difference between two groups.CONCLUSION Extracorporeal circulation(ECC) impaired the coagulation function of children with acyanotic or cyanotic congenital heart disease.The Clot Rate of children with cyanotic congenital heart disease was worse than that of children with acyanotic congenital heart disease.Cyanotic patients bleed more easily after operation.Sonoclot analyzer system could monitor patients' coagulation function accurately,and it could be used in children.
What problem does this paper attempt to address?