Abstract:The thermophilic aerobic digestion(TAD) with pure oxygen was used to treat municipal sewage sludge,and was compared to that with air aeration.The operation performance of TAD reactor with pure oxygen was investigated.The research finds that controlling DO concentration in the reactor by reasonably regulating pure oxygen aeration rate can realize TAD of sewage sludge.VSS removal efficiency in sewage sludge is more than 40% after 7 days of digestion,reaching the discharge standard of sludge from municipal WWTP in China.The TAD with pure oxygen can obtain higher oxygen utilization efficiency(about 80%) than that with air aeration(lower than 25%).Meanwhile,the pure oxygen aeration rate is much lower than air aeration rate given the same sludge stabilization.Heat loss of oxygen aeration due to off-gas discharge is much lower than that of air aeration,facilitating heat conservation in the TAD reactor.However,the high pure oxygen aeration rate may result in the accumulation of DO in the reactor.High DO concentration(more than 15 mg/L) coupled with high temperature may inhibit the activity of microorganisms that are responsible for sludge digestion.