Studies On Removal Of Microcystis And Microcystins-Lr By The Low-Power And Low-Frequency Ultrasonic Irradiation
Yang Fei,Li Xiao-Qing,Zhou Yi,Yin Li-Hong,Wu Wei,Li Yun-Hui,Pu Yue-Pu
2009-01-01
Abstract:[Objective] To reveal the effect of removal of Microcystis and degradation of microcystin-LR by ultrasonic irradiation with low-frequency and low-power and impact factors of ultrasonic algicidal technique. [Methods] Microcystis and microcystin-LR were treated with 3.4 W, 15 W, 29 W, 44 W 20 kHz low-power ultrasound, respectively. And the concentration of Microcystis was detected by spectrophotometry, the concentration of microcystins-LR was detected by HPLC. [Results] Treated by ultrasound,. the concentration of Microcystis of the treatment group was significantly lower than that of the control group. When the samples were exposed, to 20 kHz ultrasound with different powers of 15 W, 29 W, 34 W and 44 W for 600 s, the instantaneous algae removal rates were 4%, 17%, 23% and 34%, the highest removal rates of Microcystis were 43%, 90%, 93% and 88% during the next five days. When the ultrasound of 20 kHz and 44 W was applied with 15 s, 60 s, 240 s and 600 s, the instantaneous removal rates of Microcystis were 3%; 6%, 16% and 31%. The highest removal rates of Microcystis were 78%, 87%, 86% and 87% during the next four days. With the treatment of ultrasound of 20 kHz and 44 W, the degradation of microcystin-LR was founded. [Conclusion] Ultrasound with low-frequency and low-power can degrade Microcystis and microcystins-LR: The optimal parameters of ultrasound were 44 W, 20 kHz and 60 seconds.