The diagnostic value of gastric juice autofluorescence spectrum in gastric carcinoma with a standardized detecting method

ZHANG Yuening,MENG Lingmei,JIN Xinlian,GENG Qiuming,PENG Jiarou,ZHOU Liya,LIN Sanren,Xiue YAN
DOI: https://doi.org/10.3969/j.issn.1006-5709.2010.09.019
2010-01-01
Abstract:Objective To evaluate the diagnostic value of gastric juice autofluorescence spectrum in gastric carcinoma with a standardized detecting method.Methods Gastric juice was collected from patients with different gastric diseases undergoing gastroscope in our hospital from August 2006 to May 2008.Gastric juice was centrifuged,then diluted to 1∶20 with PBS solution(pH 11.0).The autofluorescence spectrum of gastric juice was detected and different fluorescence peaks were statistically analyzed.Results Autofluorescence spectrum of gastric juice was significantly different between gastric cancer and gastric benign diseases(P<0.001).The sensitivity and specificity for the diagnosis of gastric carcinoma were 80.4% and 77.4%,respectively,at a critical value of 78.5 AU.Compared with the detecting method used before,the standardized method could increase the specificity significantly(77.4% vs 71.7%,P=0.02).Conclusion Autofluorescence spectrum of gastric juice is a simple and effective method in gastric carcinoma diagnosis.Standardization of the testing parameters is contributed to the enhancement of the diagnostic specificity.
What problem does this paper attempt to address?