Capacitive Immunosensor for Transferrin Based on an O-Aminobenzenthiol Oligomer Layer

SQ Hu,ZY Wu,YM Zhou,ZX Cao,GL Shen,RQ Yu
DOI: https://doi.org/10.1016/s0003-2670(02)00067-3
IF: 6.911
2002-01-01
Analytica Chimica Acta
Abstract:A capacitance immunosensor based on an oligomer layer on gold was developed. o-Aminobenzenethiol (o-ABT) forms self-assembled layer (SAL) on polycrytalline gold surface. The SAL was polymerized electrochemically, then an oligomer of o-ABT was formed on the gold surface with some free-reacted ∼NH2 as functional groups to react with glutareldehyde (GA). The transferrin antiserum was covalently coupled on the gold surface by GA. The transferrin was determined with a detection limit of 0.12ng/ml and a linear detection range of 1.25–80.0ng/ml.